![Teac PL-D2000 Скачать руководство пользователя страница 6](http://html2.mh-extra.com/html/teac/pl-d2000/pl-d2000_service-manual_3964320006.webp)
−
6
−
1. FM, AM TRACKING VOLTAGE ADJUSTMENTS
FM/AMトラッキング電圧調整
(FM, AM)
DC VOLTMETER ........................... CONNECT TO TEST POINT R109 and GND
NO.
Band
Frequency
Adjust for
Adjustment
1
FM
87.50MHz [EUR,US]
76.00MHz [J]
1.5V
2
AM
522kHz [EUR,J]
530kHz [US]
1.5V
T101
2. AM RF ADJUSTMENT
AM RF調整
Signal Generator ........................ Connects to the AM ANT. Coil through the loop antenna.
Adjust for the indication of VTVM of the wave form of scope to be maximum.
BAND
Step
Frequency
Adjust for
Adjustment
1
612kHz [EUR,J]
610kHz [US]
Maximum sensitivity
L101
2
1404kHz [EUR,J]
1400kHz [US]
Maximum sensitivity
TC103
3
Repeat steps 1 and 2 several times.
AM
108.00MHz [EUR,US]
90.00MHz [J]
8.4V
8.3V
TC102
FM
AM
3
4
1620kHz [EUR,J]
1710kHz [US]
R109
GND
Содержание PL-D2000
Страница 8: ...8 4 EXPLODED VIEWS AND PARTS LIST EXPLODED VIEW 1...
Страница 11: ...EXPLODED VIEW 2 11...
Страница 13: ...EXPLODED VIEW 3 13...
Страница 15: ...15 5 PC BOARDS AND PARTS LIST MAIN PCB SIDE A...
Страница 16: ...16 MAIN PCB SIDE B...
Страница 18: ...18 MPEG PCB SIDE A MPEG PCB SIDE B...
Страница 19: ...19 SCART PCB SIDE A SCART PCB SIDE B...
Страница 24: ...24 PHONE PCB 7 WIRING DIAGRAM...
Страница 25: ...1 E D C B A 8 6 7 4 5 2 3 SCHEMATIC DIAGRAM PL D2000...
Страница 26: ...11 15 13 14 12 8 9 10...
Страница 28: ...HOME THEATER SYSTEM PL D2000 1 st Issue September 2001...
Страница 29: ...1 E D C B A 8 6 7 4 5 2 3 SCHEMATIC DIAGRAM PL D2000 Applicable serial number 1100XXXX YYY...
Страница 30: ...11 15 13 14 12 8 9 10...
Страница 32: ...HOME THEATER SYSTEM PL D2000 1 st Issue October 2002...