8
2
3
4
5
Set Up for Esoteric Units
This is the recommended set up for synchronization with
TEAC-ESOTERIC CD units:
P-70, X-01, UX-1, P-01, D-01
Connect WORD CLOCK OUT terminals to WORD SYNC IN
terminals of each unit using commercially available BNC
coaxial cables.
P-70: turn ON the WORD SYNC IN switch (front panel), then
set the PLL filter switch (back panel) to ‘MODE2’.
X-01: select ‘Word M1 ON’ using the CLOCK MODE button.
UX-1: select ‘Word ON’ using the CLOCK MODE button.
P-01: select ‘Rb IN’ using the WORD button.
D-01: select ‘Rb IN’ using the WORD button.
Press the STANDBY/ON button to turn the unit on.
2
1
The standby indicator will turn off.
Press the MASTER button to select which oscillator you
will use for the reference frequency.
3
<
“Rb” is recommended.
Select 44.1kHz using the FREQUENCY MODE button.
4
Select the frequency of the word clock for each line by
pressing the A, B or C button.
5
<
Set the frequency as high as the connected units will allow for
synchronization.
P-70: 88.2 kHz
X-01: 176.4 kHz
P-01: 176.4 kHz
D-01: 176.4 kHz
NOTE:
If you connect this unit to other manufacturers units, be sure
to read the manuals of those devices to confirm the frequency
range of synchronization.
Dual AES connection will require you to set the clock
frequency at one half of the audio signal frequency.
Содержание Esoteric G-0s