2.6 Adjustment of Sub-brightness
2.6.1 Input grey scale + color bar signal.
2.6.2 Press key “6” to enter sub-brightness adjustment.
2.6.3 At standard state, adjust “BRTC” , until the secondary grey just be seen.
* Do not change value “BRTS”.
2.7 Picture geometric adjustment
2.7.1 Vertical geometric adjustment
a. Input a PAL cross hatch pattern signal .
b. Press key “2” to enter Vertical geometric adjustment .
c. Use remote control to adjust one by one , watch the figure, until the center or the
corner grid has a same size .
d. When adjust vertical position , make the center of vertical intermediately.
e. In “5VSL”, the second half may blanking , adjust the first half at display range.
Remark
:
:
1 5VSC , 31 is fixed, don’t adjust .
2 5VPOS for vertical position.
3 5VAM for vertical amplitude.
4 5VSL for vertical slope.
5 5VL for vertical linearity.
6 5SCL for vertical S-correction.
7 5WBR for end of blanking time on 4:3 mode (16:9 tube).
8 5WBF for start of blanking time on 4:3 mode (16:9 tube)
.
9 5BSWBR for right side black width of blue screen .
10 5BSWBF for left side black width of blue screen.
* 5WBF/5WBR only use on matching 16:9 tube, at 4:3 picture mode, adjust
blanking time of R and F. First press “ZOOM” key switch to 4:3 mode, then adjust
5WBF and 5WBR respective to make the overscan meet the requirements.
*Adjustment is disabled when match 4:3 tube.
* 5BSWBR and 5BSWBF needn’t adjustment.
*Apply NTSC signal to adjust these registers for NTSC geometric
2.7.2 Horizontal geometry adjustment
a. Input a PAL cross hatch pattern with black and white background signal.
b. Press key “3” enter Horizontal geometric adjustment.
c. Use remote control to adjust one by one , watch the figure, until the center and the
vertical line at left and right side of the picture become straight.
Remark
:
1. Adjust 5HSH for horizontal position, data should make H center mediacy .
2. 5PAR for parallelogram adjustment.
3. 5BOW for bow adjustment.
4. Adjust 5EWW for horizontal width.
5. 5EWP for pincushion correction.
6. 5UCR for upper corner correction.
7. 5LCR for low corner correction.
Содержание 3290I
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ...CAM350 V 7 6 Wed Nov 09 17 59 34 2005 Untitled...
Страница 82: ...CAM350 V 7 6 Wed Nov 09 17 58 41 2005 Untitled...
Страница 83: ...CAM350 V 7 6 Wed Nov 09 18 02 20 2005 Untitled...