5. Solder the active device leads to the pc board.
6. Mate the plug assembly to the ADM.
Nut (2 Places)
PC Board
ADM
Plug Assembly
(Ref)
No. 2-56 Screw
(2 Places)
Active
Device
Ring
Typical ADM Horizontal (Shown) PC Board Installation
Figure 3
3.2. Receptacle
1. Cut the panel using the recommended cutout
dimensions given in Figure 4.
2. Install the receptacle in the panel cutout, and
secure it using the two No. 2-56 screws as shown in
Figure 4.
3. Connect a plug assembly to both ends of the
receptacle. Refer to Figure 4.
4. REPLACEMENT AND REPAIR
DO NOT use defective or damaged product.
Order kits through your Representative, or call
1-800-526-5142, or send a facsimile of your purchase
order to 717-986-7605, or write to:
CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608
5. REVISION SUMMARY
Revisions to this instruction sheet include:
•
Changed company name and logo
•
Removed dual-position bulkhead receptacle and
replaced superceded ADMs
•
Removed last active device from first row of
mating package in Figure 1
•
Removed all detailed information for active devices
•
Modified Paragraphs 3.1 and 3.2, and Figures 2
and 3
Single-Position Bulkhead Receptacle
Panel Cutout
Panel Mounting
5.715±0.127
[.225±.005]
7.135±0.127
[.281±.005]
14.27±0.254
[.562±.010]
2.39 [.094] Dia
(2 Places)
9.02±0.127
[.355±.005]
Note: Note to Scale
No. 2-56 Screw
(2 Places)
End of
Receptacle
Plug Assembly
Panel
Plug Assembly
End of
Receptacle
Figure 4