2.3
SETT ING UP W ITH A D MX512
CONT ROLLER
2.3-1 DM X512 ADDRESSING WITHOUT ID ADDR ESSING
STAGE 1 M OD E)
(
The figur e above sh ows a simple D MX512
layo ut w ith the s tart ing address of the first
uni t set at 1, w ith th e second set at 11 and
so o n... ( Note that when used in this w ay,
the C H 9 ID function must be inacti v e (C H9=0))
DM X512
CON TR OLL ER
●
●
●
●
●
C onne ct the DMX512 controller to the units i n series .
Each u nit has 10 DMX channels so th e DMX Addr ess es should incr ease by incr ements of
10 (e.g. 1,11,21,31... )
T he ID addr es s has no t been set so th er efore when u sing the contro ller Ch9 must
be inactiv e ( C H9=0 ) .
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
2.3-2 DM X512 ADDRESSING WITH ID ADDRESS STAGE 1 M ODE)
(
C onne ct the DMX512 controller to the units i n series
Each u nit has 10 DMX channels so th e DMX Addr ess es should incr ease by incr ements of
10 (e.g. 1,11,21,31... )
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
Each D MX addr ess may carry up to 66 separate ID a ddresses.
should be s et in the menu on each unit in asce nding values
(i .e. 1,2,3...)
ID add resses ar e accessible fr om Ch 9 on the DMX512 controller.
●
●
●
●
●
●
●
【
】
ID
Exampl e :
.... ........
7