Note:
For making connections directly to printed circuit boards using CWT-38XX-W3 or
B-155-38XX-W3 part numbers, use cable preparation described for shield termination in
Section 4.1. Adjust strip length of center conductor to accommodate desired spacing between
PCB mounting holes.
4.3.2. Assembly
1.
Position the smaller or center conductor one-step terminator so that the end is against
the folded shield, and the solder preform is visually centered over the exposed center
conductor.
2.
Heat solder preform until it melts and forms a fillet between the conductors. Allow
assembly to cool.
3.
Refold the shield so that it lies on the center conductor termination.
4.
Center the larger one-step shield he terminator over the shield.
5.
Heat solder preform until it melts and forms a fillet between the lead and the shield.
Lack of a solder fillet may indicate overheating.
4.3.3 Inspection
1. Inner conductor splice: Inspect as for wire splices in Section 4.2.3
2. Shield terminations: Inspect as for shield terminations in Section 4.1.3
4.4
Wire To Connector Terminals Or Component Leads (Discrete Wire Terminations)
4.4.1
Recommended Heating Tool: Raychem AA-400 Super Heater