USER NOTICE M210
TE CONNECTIVITY SENSORS
/// USER NOTICE M210_EN 03/2018
Page 7
ADJUSTMENT M210
I. RG1 gain resistance calculation for ±10 V output
The position of the RG1 gain resistor is shown in the schema included in this document.
RG1
GAIN RESISTANCE CALCULATION FORMULA:
7
,
8
10
435
1
4
Ve
RG
RG1
is in k
.
Ve corresponds to the sensor sensitivity in mV for Full Scale.
•
Example
:
Pressure transducer : 1 bar.
Sensitivity : 2 mV/V.
Excitation : 10 V.
RG1
= 0.885 k
.
Use the closest standard resistance value (± 1 %/50ppm/°C), in this case 887
and use the
gain potentiometer to fine tune the analogue output.
7
,
8
10
2
10000
435
1
RG