Issue 1
IR-550/ED-7-KIT
Manual Issue 1
Page 18 of 32
Key function operation continued
Auto Mode
1. Press the M/A key on the controller
2. The Controller will change from the Manual to the Auto mode, and the display will show one of the
available programmes
e.g.
3. It is now possible to scroll through pre-programmed values from P01 to P20 by pressing the
UP/DOWN arrow keys on the programme keypad
4. To change any values stored in the programme set you must enter a special key combination.
Programming Mode
1. Select the Programme you want to change P01 to P20 using the Programme UP/DOWN keys.
2. Press the RETURN and temperature DOWN key simultaneously for a minimum of 5 seconds.
3. When released the left side of the display shows an asterix (*) to confirm that you have entered
the Programming mode.
4. Time value can be adjusted using the Timer UP/DOWN keys, from 0.5 to 100 seconds in 0.5s
increments.
5. The % Power value can be adjusted using the % Power UP/DOWN keys.
6. When the required values have been set, press the RETURN key to confirm the selection and to
exit the Programming mode.
7. Pressing the foot pedal will now operate the Hand tool for the time and power shown on the
display.
8. Pressing the foot pedal a second time during the Programme will stop the sequence and the lamp
will return to the preheat condition.