Connecting Contact Alarms to a Fusion Wideband System
7-56
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
7.7
Connecting Contact Alarms to a Fusion Wideband
System
The Fusion Wideband Main Hub can generate (source) two contact alarms as well as
sense three external contact alarm.
• Alarm Source (refer to Section 7.7.1 on page 7-57)
The Fusion Wideband Main Hub has two alarm contacts, fault (major) and warn-
ing (minor). These contacts are normally-closed (NC) and will open when an inter-
nal alarm is detected.
NOTE:
The contact can be changed to normally-open (NO) with Admin-
Browser. This is not recommended since no alarm would be sent if power to
the Fusion Wideband Main Hub fails.
• Fault is activated when any faults or disconnects are detected.
• Warning is activated when any warning conditions are detected
except lockout or when the end-to-end system test is not valid.
• Alarm Sense (refer to Section 7.7.2 on page 7-60)
The Fusion Wideband Main Hub can monitor 3 external alarm contacts. Each port
can be configured for normally-open (NO) or normally-closed (NC) contacts. The
interface expects a set of floating contacts, and an external voltage source is not
required for this interface. Use AdminBrowser to monitor the port status.
Table 7-8 lists the alarm types, equipment to which the Fusion Wideband Main Hub
is connected, cable(s) used, and the faults and warnings that are detected.
Table 7-8
Alarm Types
Note that FlexWave Focus supports only faults (major errors).
Alarm
Type
Fusion
Wideband
Connected to
Cable(s) Used
Errors Detected
Source
FlexWave
5-port Alarm Daisy-Chain Cable
Faults
Source
BTS
5-port Alarm Daisy-Chain Cable
Faults and Warnings
In addition, a custom daisy-chain cable-to-BTS interface
cable is required. Make this interface cable to the desired
length and with the appropriate pin placement.
Sense
Unison
5-port Alarm Daisy-Chain Cable
and the Alarm Sense Adapter
Cable
Faults
Содержание InterReach Fusion ADCP-77-044
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 203: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620616 0 20 Rev F CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 210: ...A 10 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...
Страница 216: ...B 6 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...