5375 (08/13)
411-121100
INSTRUCTION
CLASS 1- Public
© 2021 TE Connectivity Ltd. family of companies.
All Rights Reserved.
| Indicates Change
TE Proprietary & Confidential Information
Class I Data Classification - See Policy TEC-02-04
8 of 15
Rev [1]
8 October 2021
Stop-
key
If the
stop
-key is activated while the plotter is in action, the job will pause
immediately and the pen holder will move into the top right-hand corner. The red light
will signal the interruption. Pressing the
key
again will calibrate the writing arm and
the plotter will continue with the job. The red light will go out.
Beep
off
key
After completion of the print job an acoustic signal (beep) will notify the user to take the pen
out of the pen holder and re-cap. The signal will be repeated continuously
after 20 seconds and can be turned off by using the
beep off
key.
Attention:
The pen will clog and dry up if it remains un-capped in the pen holder.
Please note:
To turn off the signal in general please press
Clear buffer
and
beep off
together and press
ON
to start the plotter. To re-activate the signal please use the same sequence.
Please note:
In the engraving mode the key is used to move the tool to the position of the indication for
standardizing the engraving needle, zero setting.
Insert
the
plotter
pen
into
the
pen
holder
Before using the
AMS 300
, insert the plotter pen with the desired tip width into the clip adapter
of the pen holder.
Important:
Only plotter pens of the types shown with HP-
adaption may be used. Using other plotter pens
and writing instruments may damage the
device.
Please note:
Prior to starting the plot, please select the pen with the desired tip width and make sure to
prime the pen on a plastic surface. Insert the pen directly into the pen holder.
The plotter always re-
calibrates prior to first plotting.