background image

408-8579

2

 of 5

Rev 

C

Figure 2

3. Holding the cable in place, close the tool handles 

until the ratchet releases.

4. Allow the tool handles to open fully and remove 

the crimped center contact from the dies.

4.2. Crimping the Ferrule 

(Figure 3)

1. Insert the crimped center contact into the 

connector body until the cable dielectric butts 

against the dielectric inside the connector body or 

until the center contact is securely positioned within 

the connector. Make sure that the braided shield is 

over the support sleeve of the connector body and 

that no strands from the shield enter the connector 

body.

2. Slide the ferrule up over the braided shield and 

onto the connector until the ferrule butts against the 

shoulder on the connector body.

3. Place the ferrule in the appropriate crimping 

chamber of the anvil die so that the shoulder on the 

connector body butts against the edge of the die.

Refer to the instruction sheet packaged with the 

connector to determine the appropriate crimping 

chamber for the ferrule.

4. With a screwdriver, adjust the ratchet wheel from 

the opposite side of the tool.

Make sure that both sides of the ferrule are started 

evenly into the crimping chamber. Do not attempt to 

crimp an improperly positioned ferrule.

5. Carefully close the tool handles until the ratchet 

releases.

Figure 3

Crimping the  Center Contact

Anvil Die

Stripped

Cable

Typical Plug

Contact

Typical Jack

Contact

Flange on End of 

Contact

Flange on End of 

Contact

Crimping Die

Crimping Die

NOTE:

 Typical Crimping Dies Shown

NOTE

i

CAUTION

!

Crimping the Ferrule

NOTE:

 Typical Crimping Dies Shown

Shoulder on

Connector Body

Butts Against

Edge of Die

Ferrule in Crimping 

Chamber on Anvil 

Die

Отзывы: