background image

Operating Manual

                                            

 

 
                                                  

Operating Manual 832 & 832M1, Rev B 

www.te.com

  

October 20, 2015

 

 

8 of 8 

 

 

TM 

TM 

Frequently Asked Questions (continued) 

Question:

  What mounting techniques and materials are recommended to achieve the best high 

frequency response? 

Response:

  To achieve the best frequency response, we recommend mounting the accelerometer 

directly to the structure to be measured. An adhesive can be used to secure the accelerometer. Take 
precautions not to short the output pads underneath the circuit board. Good frequency response can also 
be achieved by mounting the accelerometer onto a ceramic or hybrid circuit board. FR4 boards should 
be avoided for applications requiring wide bandwidth measurements since the FR4 material can impart a 
resonance to your measuring system. If attaching wires to the output pads then these need to be 
properly secured/anchored at regular intervals to minimize cable motion that can add noise and 
resonances to the output signal.

 

Question: 

What is the material composition of the plating on the solder pads? 

Response: 

The circuit board traces are Titanium-Tungsten plated with Nickel and Gold. 50micro-inches 

min of Au (99.9% pure gold per MIL-G-45204, Type III, grade A) over 50-350micro-inches of Ni (per 
AMS-QQ-N-290, Class I

 

 

 

 

 

Содержание 832

Страница 1: ...2 832M1 Rev B www te com October 20 2015 1 of 8 TM TM Model 832 832M1 Accelerometer TE Connectivity Vibration Sensors Design Center 32 Journey Suite 150 Aliso Viejo CA 92656 USA Tel 949 716 7324 www m...

Страница 2: ...eturning the unit to the factory If it is determined that factory service is required call Customer Service at the regional headquarters for an RMA number before return Returns All units being returne...

Страница 3: ...cal that the substrate has a low coefficient of expansion and that you have good mechanical coupling between the sensor and the mounting surface to ensure good transmissibility Ceramic circuit boards...

Страница 4: ...ther than 3 3Vdc will affect the full scale range of the accelerometer since the bias voltage is a function of excitation voltage The following formula can be used to calculate the full scale range of...

Страница 5: ...tions are detailed in table below 0025 0050 0100 0200 0500 Broadband Noise uV 0 1Hz 10kHz 832 300 210 160 150 160 832M1 110 90 50 40 50 832 Spectral Noise Hz 10Hz 120ug 120ug 120ug 120ug 400ug 100Hz 8...

Страница 6: ...d I was hoping for some more clarification on this statement Response The reason for the caution is the potential risk of sensitivity shift in the output after reflow soldering The units will survive...

Страница 7: ...d further information Our engineers have confirmed that the minimum excitation voltage is in fact 2 7V We specified 3 3V in our datasheet to give us some margin We also confirmed that we had previousl...

Страница 8: ...n also be achieved by mounting the accelerometer onto a ceramic or hybrid circuit board FR4 boards should be avoided for applications requiring wide bandwidth measurements since the FR4 material can i...

Страница 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information TE Connectivity 832 0500...

Отзывы: