INTRODUCTION 

This Instruction Sheet describes installation of the APT 5 Stepper Motor Kit (PN 2335312-1); a field 
replacement for the MDrive stepper motor used on TE Connectivity APT 5 machines. The kit contains a Lexium 
MDrive stepper motor, metric specified flex coupling, a motor cover assembly, mounting hardware, and a USB 
flash drive containing a software update file, a software update instructional video, and a basic CQM II 
operation instructional video. 

 

SOFTWARE 

The Lexium stepper motor requires a software update (version 3.00.41). Perform this update as follows: 

NOTE 

T

he video file “UpdatingFirmwareOnCqmII.mov” 

(located on the USB flash drive) may be used for additional guidance on 

updating the CQM II software. 

  With the machine energized, insert the flash drive into the USB port on the Host Module.  Allow a few 

seconds for the flash drive to be recognized.  Once 

recognized, press “ok”.

 

  On the host module, press the blue triangle and then the screwdriver/wrench icon. 

 

Press “Maintenance”, then press “Firmware Update”.

 

 

Press “USB”, and select file CqmII_reinstall_update_3.00.41.iso

 

 

Press “Load”.

 

  The Host Module screen will display the status of the installation.  Depending on the software version 

currently installed, the process may vary. 

Restart the system as directed by the on-screen prompts. If the screen is no longer displaying 
information or turns 

“black”, power down and remove the flash drive. Power on once again to continue 

the software update. 

  Once Host Module restarts in either case, the software will finish installing. Once completed, press 

“E

ject USB

 button. Remove the USB flash drive. 

The software update is complete. 

 

INSTALLATION PROCEDURE 

  Power off machine 

  Remove (2) M4x6.0 socket head cap screws on top of the motor cover. 

Remove cover. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1 

 

 
APT 5 Stepper Motor Kit Installation 