![TDSi eX-Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/tdsi/ex-series/ex-series_installation-manual_825998002.webp)
7 CONNECTION
TABLES
7.1
EXPERT AND EXCEL2 READER CONNECTIONS
Controller
Terminal
Reader Connection
Reader Wire Colour
23
Reader 1 IR Data
Yellow
26
Reader 1 IR Source
Blue
27 Reader
1
LED
Green
Red
White
28
Reader 1 +5 V
Black
37
Reader 2 IR Data
Yellow
40
Reader 2 IR Source
Blue
41 Reader
2
LED
Green
Red
White
42
Reader 2 +5 V
Black
Table 1 – eXpert and eXcel
2
to Microcard Reader 5002-0035
Controller
Terminal
Reader Connection
Reader Wire Colour
24 Reader
1
Data/D0
Yellow
25 Reader
1
Clock/D1
White
27 Reader
1
LED
Blue
29 Reader
1
0V
Black
30
Reader 1 +12 V
30
Reader 2 +12 V
Red
38 Reader
2
Data/D0
Yellow
39 Reader
2
Clock/D1
White
41 Reader
2
LED
Blue
43
Reader 2 0 V
Black
Table 2 – eXpert and eXcel
2
to
eXprox 5002-035x and Optica 5002-039x
Controller
Terminal
Reader Connection
Reader Wire Colour
24 Reader
1
Data
Yellow
25 Reader
1
Clock
White
27 Reader
1
LED
Blue
Red
28
Reader 1 +5 V
Green
29 Reader
1
0V
Black
38 Reader
2
Data/D0
Yellow
39 Reader
2
Clock/D1
White
41 Reader
2
LED
Blue
Red
42
Reader 2 +5 V
Green
43
Reader 2 0 V
Black
Table 3 – eXpert and eXcel
2
to
Magnetic Swipe Reader 5002-0360
7.2
EXCEL2 DOOR FURNITURE CONNECTIONS
Controller Terminal
Equipment Connection
18
Door 1 lock relay pole
19
Door 1 lock relay n/o
32
Door 2 lock relay pole
33
Door 2 lock relay n/o
Table 4 - eXpert and eXcel
2
connections to lock (fail-locked condition)
Controller Terminal
Equipment Connection
17
Door 1 lock relay n/c
18
Door 1 lock relay pole
31
Door 2 lock relay n/c
32
Door 2 lock relay pole
Table 5 - eXpert and eXcel
2
connections to lock (fail-open condition)
Controller Terminal
Equipment Connection
2+
Door lock Supply (1 A max.)
2-
Door lock 0 V
3+
Door lock Supply (1 A max.)
3-
Door lock 0 V
Table 6 - eXpert and eXcel
2
connections for power supply for locks
Controller Terminal
Equipment Connection
20
Door 1 door sense input
21
Door 1 door sense 0 V
34
Door 2 door sense input
35
Door 2 door sense 0 V
Table 7 - eXpert and eXcel
2
connections for door sensors
Controller Terminal
Equipment Connection
21
Door 1 door egress 0 V
22
Door 1 door egress input
35
Door 2 door egress 0 V
36
Door 2 door egress input
Table 8 - eXpert and eXcel
2
connections for egress buttons
7.3
EXCEL2 INPUT AND RELAY CONNECTIONS
Controller Terminal
Equipment Connection
34 Input
3
35
0 V (for inputs 3 & 4)
36 Input
4
50 Input
5
51
0 V (for inputs 5 & 6)
52 Input
6
53 Input
7
54
0 V (for inputs 7 & 8)
55 Input
8
Table 9 – eXpert and eXcel
2
Input Connections
Controller Terminal
Equipment Connection
31 Relay
2
n/c
32 Relay
2
pole
33 Relay
2
n/o
44 Relay
3
n/c
45 Relay
3
pole
46 Relay
3
n/o
47 Relay
4
n/c
48 Relay
4
pole
49 Relay
4
n/o
Table 10 – eXpert and eXcel
2
Relay Connections
7.4 EXCEL2
COMMUNICATIONS
CONNECTIONS
PC 9-way
PC 25-way
Controller
Terminal
Function
2 3 7 Receive
Data
(Rx)
3 2 6 Transmit
Data
(Tx)
5 7 5 Ground
Table 11 - eXpert and eXcel
2
RS-232 Connections (Direct Communications)
IP Connected Controller
RS-485
Connected
Controller
Function
1 1
RS-485
Rx
B
2 2
RS-485
Rx
A
3 3
RS-485
Tx
B
4 4
RS-485
Tx
A
Controller Chassis
Controller Chassis
Cable Screen
Table 12 - Connection when using an IP Enabled Controller as an Ethernet Converter
For communications using a separate serial to Ethernet converter or serial to RS-485
converter, please refer to the documentation supplied with those devices.
7.5 EXCEL4
READER
CONNECTIONS
Controller
Terminal
Reader Connection
Reader Wire Colour
14 Reader
1
Data/D0
Yellow
15 Reader
1
Clock/D1
White
16 Reader
1
LED
Blue
17
Reader 1 +12 V
Red
18 Reader
1
0V
Black
25 Reader
2
Data/D0
Yellow
26 Reader
2
Clock/D1
White
27 Reader
2
LED
Blue
28
Reader 2 +12 V
Red
29
Reader 2 0 V
Black
30 Reader
3
Data/D0
Yellow
31 Reader
3
Clock/D1
White
32 Reader
3
LED
Blue
28
Reader 3 +12 V
Red
29
Reader 3 0 V
Black
41 Reader
4
Data/D0
Yellow
42 Reader
4
Clock/D1
White
43 Reader
4
LED
Blue
44
Reader 4 +12 V
Red
45
Reader 4 0 V
Black
Table 13 – eXcel
4
to
eXprox 5002-035x, Optica 5002-039x and Digital IR 5002-1781
Controller
Terminal
Reader Connection
Reader Wire Colour
14 Reader
1
Data/D0
Yellow
15 Reader
1
Clock/D1
White
16 Reader
1
LED
Blue
12
Reader 1 +5 V
Red
18 Reader
1
0V
Black
25 Reader
2
Data/D0
Yellow
26 Reader
2
Clock/D1
White
27 Reader
2
LED
Blue
39
Reader 2 +5 V
Red
29
Reader 2 0 V
Black
30 Reader
3
Data/D0
Yellow
31 Reader
3
Clock/D1
White
32 Reader
3
LED
Blue
39
Reader 3 +5 V
Red
29
Reader 3 0 V
Black
41 Reader
4
Data/D0
Yellow
42 Reader
4
Clock/D1
White
43 Reader
4
LED
Blue
40
Reader 4 +5 V
Red
45
Reader 4 0 V
Black
Table 14 – eXcel
4
to
Magnetic Swipe Reader 5002-0360
7.6
EXCEL4 DOOR FURNITURE CONNECTIONS
Controller Terminal
Equipment Connection
20
Door 1 lock relay pole
21
Door 1 lock relay n/o
34
Door 2 lock relay pole
35
Door 2 lock relay n/o
47
Door 3 lock relay pole
48
Door 3 lock relay n/o
53
Door 4 lock relay pole
54
Door 4 lock relay n/o
Table 15 – eXcel
4
connections to lock (fail-locked condition)
Controller Terminal
Equipment Connection
19
Door 1 lock relay n/c
20
Door 1 lock relay pole
33
Door 2 lock relay n/c
34
Door 2 lock relay pole
46
Door 3 lock relay n/c
47
Door 3 lock relay pole
52
Door 4 lock relay n/c
53
Door 4 lock relay pole
Table 16 – eXcel
4
connections to lock (fail-open condition)
Controller Terminal
Equipment Connection
2+
Door lock Supply (1 A max.)
2-
Door lock 0 V
3+
Door lock Supply (1 A max.)
3-
Door lock 0 V
Table 17 – eXcel
4
connections for power supply for locks
Controller Terminal
Equipment Connection
22
Door 1 door sense input
23
Door 1 door sense 0 V
36
Door 2 door sense input
37
Door 2 door sense 0 V
49
Door 3 door sense input
50
Door 3 door sense 0 V
55
Door 4 door sense input
56
Door 4 door sense 0 V
Table 18 – eXcel
4
connections for door sensors
Table 19 – eXcel
4
connections for egress buttons
7.7
EXCEL4 COMMUNICATIONS CONNECTIONS
PC 9-way
PC 25-way
Controller Terminal
Function
2 3 7
Receive
Data
(Rx)
3
2
6
Transmit Data (Tx)
5 7 5
Ground
Table 20 – eXcel
4
RS-232 Connections (Direct Communications)
Controller Terminal
Equipment Connection
23
Door 1 door egress 0 V
24
Door 1 door egress input
37
Door 2 door egress 0 V
38
Door 2 door egress input
50
Door 3 door egress 0 V
51
Door 3 door egress input
56
Door 4 door egress 0 V
57
Door 4 door egress input
8
TECHNICAL SPECIFICATION – POWER SUPPLY
Input Voltage
230 Vac n10 %/-15 %
Input Frequency
50 Hz
Mains Input Fuse
T2A 20 mm 230 v HRC
Output Voltage
13.6 to 14.0 VDC on mains power
10.5 to 12.3 VDC on battery standby
Output Load Current
3 A
Output Ripple
50 mV
p-p
max @ 230 V ±10 %
600 mV
p-p
max @ 230 V -15%
Output Load Regulation
5 %
Load Output Fuse
F3.15 A 20 mm
Overload Protection
Electronic shutdown until overload/short circuit removed
Standby Battery
Capacity/Recharge Time
1 x 7 Ah Sealed Lead Acid/13 hours (to 80% capacity)
Standby Battery Charge
Current
0.5 A
Standby Battery Fuse
Protection
F3.15 A 20 mm
Green LED
Mains present
Red LED
Fault present: output fuse fail
Visual Indications
Amber LED
Battery Standby operation
Storage Temperature Range
-20 °C to +80 °C
Operating Temperature Range
-5 °C to + 45 °C
Operating Humidity
<95 %RH, non-condensing