background image

2

OPERATION MANUAL

1.INSPECTION

-After unpacking the pump, please check if it has been damaged during transport. If so, please

contact

TDRFORCE

online services at the first time.

2.INSTALLATION

-Make sure that the main voltage corresponds to the voltage specified on the motor rating plate.

-Place the pump as near as possible to the suction tank.

-Do not submit the pump body to mechanical stress.

-The pump must be sheltered from weather ( sun- rain- wind- snow- chill).

-The motor must be absolutely grounded before any other operation.

-The suction pipe diameter must always be bigger than the suction port. Always fit a foot valve

with strainer on the suction pipe. Both suction and delivery pipe must be well fastened.

3.STARTING THE PUMP

-Fill the pump body with water. Only after being filled with water will the pump be ready to start.

-Dry running could damage the pump. The lack water protection circuit will automatically shut off

the pump after 5-minute running.

-Check that the pump does not run out of the operating data.

-The pump could be only used in fresh water circulating.

4.MAINTENANCE

-Pumps do not require any particular maintenance.

-If the pump remain unused for a long period of time, we recommend emptying it to prevent

formation of deposits or increase of water volume due to frozen water, which could tear the fixing

bolts or cracking the pump body.

-When starting the pump again, refill it and check that the shaft runs free.

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

www.tdrpump.com

Содержание JETS-60

Страница 1: ...INSTRUCTION MANUAL with Warranty Card BOOSTER PUMP JETS 60 JETS 80 JT 100 w w w t d r p u m p c o p c o m w w w t d r p u m p c o m w w w t d r p u m p c o m w w w w...

Страница 2: ...r 550W 3 4Hp Frequency 60Hz Rated Working Pressure 2 bar Connection 1 Max Working Pressure 4 bar Max Working Temperature 60 140 Max Head 40m 131ft Max Flow 17 GPM JT 100 Input Voltage 110 120V Power 7...

Страница 3: ...uction and delivery pipe must be well fastened 3 STARTING THE PUMP Fill the pump body with water Only after being filled with water will the pump be ready to start Dry running could damage the pump Th...

Страница 4: ...r Replace the controller Replace the controller Fix the leakage Intermittent pump working The electronic card is broken The pump does not provide sufficient pressure Presence of leaks Replace the cont...

Страница 5: ...rting operation archived the unit is programmed to perform all the pump control operations automatically When particular operational breakdowns occur such as water failure obstruction of the suction p...

Страница 6: ...ill show you how to make correct connection Wrong connection will destroy the whole electronic circuit Cable used for connection must be a three wired one with compulsory grounding end It shall have t...

Страница 7: ...rranty card 4 Valid evidence showing product problems shall be provided in the contact such as videos photos or detailed descriptions 5 Warranty card shall be filled out and attached with the return p...

Отзывы: