TDK Xeta Half Brick-iHG Скачать руководство пользователя страница 12

 

 

 

 

 

 

 

   

 

 

Data Sheet: Xeta

 iHG48070A033V, 3.3V/70A Output Half Brick Series

 

 

©2008  TDK Innoveta Inc.  
iHG Datasheet   2008-05-15   Revision 1.1 

 

 (877) 498-0099

 

12/16 

 
the  derating  curve.  For  improved  design 
margins and enhanced system reliability, the 
power  module  may  be  operated  at 
temperatures  below  the  maximum  rated 
operating temperature. 
 
Heat  transfer  by  convection  can  be 
enhanced by increasing the airflow rate that 
the  power  module  experiences.    The 
maximum  output  current  of  the  power 
module is a function of ambient temperature 
(T

AMB

)  and  airflow  rate  as  shown  in  the 

thermal  performance  figures  on  the  thermal 
performance  page  for  the  power  module  of 
interest.    The  curve  in  the  figures  is  shown 
for natural convection and  up.  The data for 
the  natural  convection  condition  has  been 
collected  at  0.3  m/s  (60  ft/min)  of  airflow, 
which  is  the  typical  airflow  generated  by 
other  heat  dissipating  components  in  many 
of  the  systems  that  these  types  of  modules 
are  used  in.    In  the  final  system 
configurations, the airflow rate for the natural 
convection  condition  can  vary  due  to 
temperature  gradients  from  other  heat 
dissipating components. 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Содержание Xeta Half Brick-iHG

Страница 1: ...ay result from its use No license is granted by implication or otherwise under any patent or patent rights of TDK Innoveta TDK Innoveta components are not designed to be used in applications such as l...

Страница 2: ...50 to 10 and remote sensing are standard features enhancing versatility Standard Features RoHS compliant Standard Half Brick footprint Optimized output power 231W Full load efficiency 90 typical Wide...

Страница 3: ...ion OTP Over Temperature Protection Product Offering Code Input Voltage Output Voltage Output Current Maximum Output Power Efficiency iHG48070A033V 002 R 36V to 75V 3 3V 70A 231W 90 TDK Innoveta Inc 3...

Страница 4: ...specified tolerances are x x 0 5 0 02 x xx and x xxx 0 25 0 010 Pin Assignment PIN FUNCTION PIN FUNCTION 1 Vin 7 Trim 2 On Off 8 Sense 3 N A 9 Vout 4 Vin 5 Vout 6 Sense Pin base material is copper wit...

Страница 5: ...nom on off on Io Io max Tc 25 C Startup Delay Time from on off 3 mS Vo 0 to 0 1 Vo nom Vin Vi nom Io Io max Tc 25 C Output Voltage Rise Time 24 mS Io Io max Tc 25 C Vo 0 1 to 0 9 Vo nom Standby Curren...

Страница 6: ...e 0 1uF ceramic capacitors and one 220uF electrolytic capacitor see input output ripple measurement figure BW 20MHz Output Voltage Adjustment Range 50 110 Vo nom Output Voltage Sense Range Vo nom Dyna...

Страница 7: ...42 49 56 63 70 Output Current A P o w e r D is s ip a tio n W Vin 36V Vin 48V Vin 75V Vin 60V Efficiency vs Input Voltage at Ta 25C test in socket Power Dissipation vs Input Voltage at Ta 25C Start u...

Страница 8: ...4 21 28 35 42 49 56 63 70 Output Current A O u tp u t V o lta g e V Vin 36V Vin 48V Vin 75V Vin 60V 3 295 3 296 3 297 3 298 3 299 3 3 36 40 44 48 52 56 60 64 68 72 76 Input Voltage V O u tp u t V o lt...

Страница 9: ...1 877 498 0099 9 16 Electrical Characteristics continued 0 1 10 100 1000 0 10 20 30 40 Decrease in Output Voltage T rim R e s is ta n c e k 10 100 1000 10000 0 2 4 6 8 10 Increase in Output Voltage T...

Страница 10: ...in system design TDK Innoveta recommends that the user verify the module s thermal performance in the end application The critical component should be thermo coupled and monitored and should not exce...

Страница 11: ...ent in networking telecom wireless and advanced computer systems operates in similar environments and utilizes vertically mounted printed circuit boards PCBs or circuit cards in cabinet racks The powe...

Страница 12: ...of the power module is a function of ambient temperature TAMB and airflow rate as shown in the thermal performance figures on the thermal performance page for the power module of interest The curve in...

Страница 13: ...t against thermal damage The module will auto restart as the unit is cooled below the over temperature threshold A latched over temperature protection option is also available Consult the TDK Innoveta...

Страница 14: ...voltage is trimmed the output over voltage set point is not adjusted Trimming the output voltage too high may cause the output over voltage protection circuit to be triggered Remote Sense The power mo...

Страница 15: ...in which the DC DC power module is installed the power module must be installed in compliance with the creepage and clearance requirements of the safety agency The isolation is basic insulation For a...

Страница 16: ...ertified assembly plants Warranty TDK Innoveta s comprehensive line of power solutions includes efficient high density DC DC converters TDK Innoveta offers a three year limited warranty Complete warra...

Отзывы: