background image

 

 

 

piezobrush PZ2 

Operating Instructions for Handheld Device 

Series/Type: 

 

PZ2 - Prototypes 

Ordering code:   

Z63000Z2910Z1Z62 

Date: 

 

2019-06-12 

Version: 

 

2.0 

 TDK Electronics AG 2019. Reproduction, publication and dissemination of this publication, enclosures hereto and the 

information contained therein without TDK Electronics' prior express consent is prohibited. 

Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then 
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.  
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! 

Identification/Classification 1  
(header 1 + top left bar): 

piezobrush PZ2  

Identification/Classification 2  
(header 2 + bottom left header bar): 

Operating Instructions for Handheld Device 

Ordering code: (top right header bar) 

Z63000Z2910Z1Z62 

Series/Type: (bottom right header bar) 

PZ2 - Prototypes 

Preliminary data (optional):  

Preliminary data 

Department: 

 

Date: 

2019-06-12 

Version: 

2.0 

 

 

 

 

 

Содержание piezobrush PZ2

Страница 1: ...n headers and footers Please fill in the table and then change the color to white This ensures that the table disappears invisible for the customer PDF Don t change formatting when entering or pasting...

Страница 2: ...4 Technical data 8 5 Transport storage 8 6 Installation 8 7 Special Note on the operation of the plasma process 9 7 1 General description 9 7 2 Notes on the correct handling of the substrates to be t...

Страница 3: ...pliance may result in serious or fatal injury 2 1 Residual risks This device has been manufactured in accordance with the current state of the art However it is impossible to eliminate residual risks...

Страница 4: ...nd assure electromagnetic compatibility with other electrical and electronic equipment in the immediate vicinity of the system Ensure that Operating personnel have read and understood these operating...

Страница 5: ...dering code The piezobrush PZ2 handheld device can be ordered by using ordering code Z63000Z2910Z1Z62 3 2 Correct use The piezobrush PZ2 is a handheld device for generating technical plasma It is used...

Страница 6: ...e end of this document 3 4 Description of device The individual parts of the generator are shown and named in the diagram below These terms are used throughout the operating instructions No Component...

Страница 7: ...es Preliminary data 2019 06 12 Please read Cautions and warnings and Page 7 of 17 Important notes at the end of this document No Component description 8 External power plug with changeable plugs for E...

Страница 8: ...arameters see chapter 7 Treatment speed 10 20 mm s Operating conditions Air humidity 80 rel non condensing Temperature 10 40 C 50 104 F Storage conditions Air humidity 80 rel non condensing Temperatur...

Страница 9: ...assisted adhesive bonded joints Plugging and sealing Plasma induced reduction of metal surfaces Chemical free bleaching of textiles Plasma decontamination of fabric Handling of food products for qual...

Страница 10: ...Carrying out surface treatment Depending on the type and condition of your substrate pre cleaning before the plasma process can improve the overall outcome The effect of the treatment depends on the...

Страница 11: ...harge and cause skin irritations and might be slightly painful Attention Damage to device The plasma generator may be damaged if used without gas flow resulting in a lack of the cooling medium needed...

Страница 12: ...nozzle 8 4 Nearfield Nozzle The nearfield nozzle has been specially developed for the treatment of conductive substrates Caution In operation the nozzle insert can become hot Do not touch the nozzle...

Страница 13: ...rator with a cloth dampened in water Do not use solvents to clean the plasma generator Attention Damage to device Never touch the piezo component on the front side of the device with sharp edged objec...

Страница 14: ...De energize device Switch on again Piezo component broken the plasma generator is defective Contact customer service Shutdown due to overheating Allow the plasma generator to cool down Ensure that th...