TDK-Lambda Americas Inc.
2019
11
WARNING When AC voltage is applied to the Evaluation Test Board the 450V bulk capacitors ARE
energized at ALL time
2.)
Remote On/Off (SW200)
SW200
, Will either turn the module On or put it into Standby
3.)
Auxiliary Voltage (DS301)
DS301
, The LED will Turn-On when the 450Vdc bulk capacitors
are energized above 70Vdc
4.)
Power Good (DS300)
DS300
, The LED will Turn-On once the module’s output has
been Turned-On
5.)
Test Points
TP301
Monitor Auxiliary Voltage
TP302
Monitor Power Good Signal
1.5
Setting the PMBus Address
•
The PMBus address setting on the Evaluation Test Board comes with the Factory default setting,
Address: 0x33 (Hex) (R318 & R319 are populated with 41.2K)
•
To change PMBus address to a different address R318 (AD1) and R319 (AD2) must be populated
with appropriate resistor values located in “PFH PMBus Specification Customer Release”
document.
Example:
Suppose a PMBus address of 0x51 was desired instead of 0x33.
R318 (PMBus AD1):
Remove 41.2K (0805 Resistor)
Populate with 14K (0805 Resistor)
R319 (PMBus AD2):
Remove 41.2K (0805 Resistor)
Populate with 69.8K (0805 Resistor)