background image

(1/3)

002-03 / 20120316 / ef441_nb.fm

• All specifications are subject to change without notice.

Ultrasonic Nebulizer Units
Incorporate Type

NB Series

The TDK ultrasonic humidifier unit was the first such product in the 

world to be developed. There is an increasing need for indoor 

humidification due to the proliferation of clean air heat pumps and 

central heating systems. 

When the appropriate amount of humidity is added as determined 

by the relationship between humidity and sensible temperature 

(temperature perceived by the body), humidification is advanta-

geous from the standpoint of both health and reduced energy con-

sumption. 

In addition to such home uses, these ultrasonic humidifier units 

have numerous advantages for humidification of vegetable show-

cases, preservation and growth of agricultural products, industrial 

applications, etc. A wide variety of standard units are available 

from TDK.

ELECTRICAL CHARACTERISTICS

• The character at the end of the product number indicates the transducer’s direction of tilt.

EXAMPLE OF ATOMIZATION CHAMBER CONSTRUCTION

TYPICAL TRANSDUCER INSTALLATION

TYPICAL CHARACTERISTICS OF HUMIDIFIER UNITS

VOLTAGE CHARACTERISTICS(48V)

WATER TEMPERATURE CHARACTERISTICS(48V)

WATER LEVEL CHARACTERISTICS

Part No.

NB-59S-09S-0

NB-80E-01-H

Rated input voltage

Eac(V)

48±10%

Edc(V)

12±10%

Power consumption (W)

30±5

13.2max.

Mist output ratio (l/h)

450

10

–3

min.

(150+100, –50)

10

–3

Ultrasonic frequency (kHz)

1600 to 1750

2350 to 2600

Normal water level (mm)

40

35

External potentiometer (k

)

10

Operating water temperature range (°C)

0 to 45

0 to 45

Water quality

Drinking water

Drinking water

Transducer element life (h)

10000

5000

Cooling method

Water cooled

Air cooled

Parallel connected operation

Yes

Yes

Weight (g)

60

60

Main application

Various humidity control systems

Microparticle applications such as for medical use

Air-flow

Mist

Mist discharge tube

Atomization chamber

Float switch

Power transformer

Ultrasonic humidifier unit

Fan moter

Transducer

Drive

circuit

Water tank

35 to 45mm

13mm

Transducer

(tilted about 7°)

The direction of
water column

Air-flow

 The tilt direction of transtucer will be the

  same as the direction of water column. 

The arrows indicate the tilt direction 
of the transducer.

Tilt directions of the transducer

NB-59S-09S Type

Transducer

+40

+20

48V+10    

(52.8V)

+20

(57.6V)

+30

(62.4V)

–20

(38.4V)

–10

(43.2V)

–30

(33.6V)

–60

–40

–20

Input voltage ratio(%)

Mist generation

ratio(%) [ 0%=

550

( ml/hr

)]

700

600

500

Mist output

( ml/hr

)

Water temperature(˚C)

10

20

30

40

50

600

400

200

Mist output

( ml/hr

)

Water level(mm)

30

35

40

45

50

48V series

24, 12V series

Отзывы: