(4/30)
004-02 / 20070523 / ea122_jbw.fm
• All specifications are subject to change without notice.
JBW15W Type
SPECIFICATIONS AND STANDARDS
∗
Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
• Optional input, output cable kits are available at a separate price.
Part No.
JBW05-3R0
JBW12-1R3
JBW15-1R0
JAW24-0R7
Rated output voltage and current
∗
5V • 3A
12V • 1.3A
15V • 1.0A
24V • 0.7A
Maximum output power
W
15
15.6
15
16.8
Input conditions
Input voltage Eac/Edc
V
85 to 265[Rating: 100 to 240]/110 to 370
Input frequency
Hz
47 to 440[Rating: 50 to 60](Single phase)
Input current
A
0.36typ./0.43max.[AC.100V]0.2typ./0.24max.[AC.240V]
Fuse rating
A
2[AC.250V, built-in]
Surge current
A
15typ./19.5max.[AC.100V]30typ./41max.[AC.240V] 1st surge current, cold start, reset after 1s minimum.
Leakage current
mA
0.2typ./0.75max.[AC.100V, 60Hz]0.3typ./0.75max.[AC.240V, 60Hz]
Power factor
0.6typ./0.45typ.[AC.100/240V]
Efficiency
%
72typ.[AC.100V]
76typ.[AC.100V]
76typ.[AC.100V]
78typ.[AC.100V]
%
72typ.[AC.240V]
74typ.[AC.240V]
74typ.[AC.240V]
76typ.[AC.240V]
Output characteristics
Output voltage Edc
V
5
12
15
24
Voltage variable range Edc
V
Fixed
Fixed
Fixed
Fixed
Maximum output current
A
3
1.3
1
0.7
Minimum output current
A
0
0
0
0
Overvoltage threshold Edc
V
5.75min.
13.8min.
17.25min.
27.6min.
Overcurrent threshold
A
3.15min.
1.37min.
1.05min.
0.74min.
Voltage
stability
Source effect
%
0.4max.[Within the input voltage range]
Load effect
%
0.8max.[0 to 100% load]
Temperature effect
%
1max.[Ambient temperature: –10 to +50°C]
Drift(Time effect)
%
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%
±4max.[50 to 100% sudden load change]
Ripple Ep-p
mV
80max.
120max.
120max.
120max.
Ripple noise Ep-p
mV
120max.
150max.
150max.
150max.
Start up time
ms
200max.(25typ.)/100max.(25typ.)[AC.100/240V]
200max.(40typ.)/100max.(40typ.)[AC.100/240V]
Hold up time
ms
13typ./150typ. [AC.100/240V]
Auxiliary functions
Indicator display
No
Overvoltage protection
Zenor diode clamp method, output may latch up depending on the condition.
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Parallel operation
Impossible
Series operation
Impossible
Output voltage external variable function
No
Standards
Safety standards
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
Noise terminal voltage
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
Input harmonics current requirement
No
Constructions
External dimensions
mm
22.6
×
50
×
95[H
×
W
×
L]
Weight
g
80max.
Mounting method
Can be attached to 1 side.
Case material
No(PWB Material: CEM3)