Advanced Data Sheet: Veta

 iHA48060A012V*, 1.2V/60A Output Half Brick 

Series

 

©2007  TDK Innoveta Inc.  
iHA Datasheet   040207    

 

'

 (877) 498-0099

 

11/16 

 

Thermal Management:  

 
An important part of the overall system 
design process is thermal management; 
thermal design must be considered at all 
levels to ensure good reliability and lifetime 
of the final system. Superior thermal design 
and the ability to operate in severe 
application environments are key elements 
of a robust, reliable power module. 
 
A finite amount of heat must be dissipated 
from the power module to the surrounding 
environment. This heat is transferred by the 
three modes of heat transfer: convection, 
conduction and radiation. While all three 
modes of heat transfer are present in every 
application, convection is the dominant 
mode of heat transfer in most applications. 
However, to ensure adequate cooling and 
proper operation, all three modes should be 
considered in a final system configuration. 
 
The open frame design of the power module 
provides an air path to individual 
components. This air path improves 
convection cooling to the surrounding 
environment, which reduces areas of heat 
concentration and resulting hot spots. 
 

Test Setup:

 The thermal performance data 

of the power module is based upon 
measurements obtained from a wind tunnel 
test with the setup shown in the wind tunnel 
figure. This thermal test setup replicates the 
typical thermal environments encountered in 
most modern electronic systems with 
distributed power architectures. 

The 

electronic equipment in networking, telecom, 
wireless, and advanced computer systems 
operates in similar environments and utilizes 
vertically mounted (PCBs) or circuit cards in 
cabinet racks. 
 
The power module is mounted on a 0.062 
inch thick, 6 layer, 2oz/layer PCB and is 
vertically oriented within the wind tunnel. 
Power is routed on the internal layers of the 
PCB. The outer copper layers are thermally 
decoupled from the converter to better 
simulate the customer’s application. This 
also results in a more conservative derating. 
 
The cross section of the airflow passage  is 
rectangular with the spacing between the 

top of the module and a parallel facing PCB 
kept at a constant (0.5 in). The power 
module’s orientation with respect to the 
airflow direction can have a significant 
impact on the unit’s thermal performance. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Thermal Derating:

 

For proper application of 

the power module in a given thermal 
environment, output current derating curves 
are provided as a design guideline in the 
Thermal Performance section for the power 
module of interest. The module temperature 
should be measured in the final system 
configuration to ensure proper thermal 
management of the power module. For 
thermal performance verification, the module 
temperature should be measured at the 
location indicated in the thermal 
measurement location figure in the Thermal 
Performance section for the power module 
of interest. In all conditions, the power 
module should be operated below the 
maximum operating temperature shown on 
the derating curve. For improved design 
margins and enhanced system reliability, the 
power module may be operated at 
temperatures below the maximum rated 
operating temperature. 
 

AIRFLOW 

Air Velocity and Ambient Temperature 
 Measurement Location

 

O
W

 

12.7 
(0.50)

 

Module 
Centerline

 

Air Passage 
Centerline

 

Adjacent PCB 

76  (3.0) 

Wind Tunnel Test Setup Figure  

Dimensions are in millimeters (inches) 

 

Содержание iHA48011A280V-000

Страница 1: ...license is granted by implication or otherwise under any patent or patent rights of TDK Innoveta TDK Innoveta components are not designed to be used in applications such as life support systems wherein failure or malfunction could result in injury or death All sales are subject to TDK Innoveta s Terms and Conditions of Sale which are available upon request Specifications are subject to change with...

Страница 2: ...ility system A wide output voltage trim range and remote sensing are standard features enhancing versatility Standard Features Standard Half Brick footprint High efficiency 83 93 5 typical Wide output trim voltage Up to 60A of true usable current Industry leading output power up to 350W Monotonic start up Monotonic start up into a pre biased output Basic insulation 1500 Vdc Constant switching freq...

Страница 3: ...0 36V to 75V 5 0V 60A 300W 90 iHA48040A050V 000 36V to 75V 5 0V 40A 200W 91 iHA48025A120V 000 36V to 75V 12 0V 25A 300W 91 5 iHA48013A240V 000 36V to 75V 24 0V 12 5A 300W 91 iHA48011A280V 000 36V to 75V 28 0V 11A 308W 91 iHA48016A280V 000 40V to 60V 28 0V 16A 450W 93 5 TDK Innoveta Inc 3320 Matrix Drive Suite 100 Richardson Texas 75082 Phone 877 498 0099 Toll Free 469 916 4747 Fax 877 498 0143 Tol...

Страница 4: ...asheet 040207 877 498 0099 4 16 Mechanical Specification Unless otherwise specified tolerances are x x 0 5 mm x xx 0 02 in x xx 0 25 mm x xxx 0 010 in Recommended Hole Pattern top view Pin Assignment PIN FUNCTION PIN FUNCTION 1 Vin 7 Trim 2 On Off 8 Sense 3 Case Omit optional 9 Vout 4 Vin 5 Vout 6 Sense ...

Страница 5: ...age 15 mS Vo 0 to 0 1 Vo nom on off on Io Io max Tc 25 C Startup Delay Time from on off 10 mS Vo 0 to 0 1 Vo nom Vin Vi nom Io Io max Tc 25 C Inrush Transient 0 06 A 2 s Engineering estimate Electrical Data Input Characteristic Min Typ Max Unit Notes Conditions Maximum Input Current 2 6 A Vin 0 to Vin max Io max Vo Vo nom Output Voltage Rise Time 20 mS Io Io max Tc 25 C Vo 0 1 to 0 9 Vo nom Input ...

Страница 6: ... 15 18 mVrms Measured across one 47uF one 1uF and one 0 1uF ceramic capacitors see input output ripple measurement figure BW 20MHz Output Voltage Adjustment Range 50 110 Vo nom Output Voltage Sense Range 10 Vo nom Dynamic Response Recovery Time Transient Voltage 0 25 35 mS mV di dt 0 1A uS Vin Vin nom load step from 50 to 75 of Io max For applications with large step load changes and or high di dt...

Страница 7: ...001 Typical Power Dissipation vs Output current at Ta 25 degrees iHA48060A012V 001 Load Regulation 1 2015 1 202 1 2025 1 203 1 2035 1 204 1 2045 1 205 6 12 18 24 30 36 42 48 54 60 Output Current A Output Voltage V Vin 36V Vin 48V Vin 75V Ta 25 Deg C iHA48060A012V 001 Typical Output Voltage vs Load Current at Ta 25 degrees iHA48060A012V 001 Typical startup characteristic from on off at full load Up...

Страница 8: ... Voltage 0 0 4 0 8 1 2 1 6 30 32 34 36 38 Input Voltage V Output Voltage V Io_min 6 03A Io_mid 30 26A Io_max 60 09A Ta 25 Deg C Vin decreasing turn off Vin increasing turn on iHA48060A012V 001 Typical Input Current vs Input Voltage Characteristics at Ta 25 degrees iHA48060A012V 001 Typical Output Voltage vs Input Voltage Turn on Turn off Characteristics low voltage at Ta 25 degrees Output Voltage ...

Страница 9: ...10 100 1000 0 65 0 70 0 75 0 80 0 85 0 90 0 95 1 00 1 05 1 10 1 15 1 20 Desired Decreased Output Voltage V T r i m R e s i s t a n c e k Ω 0 01 0 10 1 00 10 00 1 20 1 22 1 24 1 26 1 28 1 30 1 32 Desired Increased Output Voltage V Trim Resistance k Ω iHA48060A012V 001 Trim down curve for output voltage adjustment iHA48060A012V 001 Trim up curve for output voltage adjustment ...

Страница 10: ...rrent vs ambient temperature at nominal input voltage for airflow rates natural convection 0 3 m s 60lfm to 3 0m s 600lfm Airflow from Vout to Vout with the module output side on the left The thermal curves provided are based upon measurements made in TDK Innoveta s experimental test setup that is described in the Thermal Management section Due to the large number of variables in system design TDK...

Страница 11: ...imilar environments and utilizes vertically mounted PCBs or circuit cards in cabinet racks The power module is mounted on a 0 062 inch thick 6 layer 2oz layer PCB and is vertically oriented within the wind tunnel Power is routed on the internal layers of the PCB The outer copper layers are thermally decoupled from the converter to better simulate the customer s application This also results in a m...

Страница 12: ...ings for attaching a heatsink or cold plate The addition of a heatsink can reduce the airflow requirement and ensure consistent operation and extended reliability of the system With improved thermal performance more power can be delivered at a given environmental condition Standard heatsink kits are available from TDK Innoveta for vertical module mounting in two different orientations longitudinal...

Страница 13: ...re the modules may turn off to safeguard the power unit against thermal damage The module will auto restart as the unit is cooled below the over temperature threshold Remote On Off The power modules have an internal remote on off circuit The user must supply an open collector or compatible switch between the Vin pin and the on off pin The maximum voltage generated by the power module at the on off...

Страница 14: ...age too high may cause the output over voltage protection circuit to be triggered Remote Sense The power modules feature remote sense to compensate for the effect of output distribution drops The output voltage sense range defines the maximum voltage allowed between the output power terminals and output sense terminals and it is found on the electrical data page for the power module of interest If...

Страница 15: ...s of the safety agency The isolation is basic insulation For applications requiring basic insulation care must be taken to maintain minimum creepage and clearance distances when routing traces near the power module As part of the production process the power modules are hi pot tested from primary and secondary at a test voltage of 1500Vdc The case pin is considered a primary pin for the purpose of...

Страница 16: ...ted warranty Complete warranty information is listed on our web site or is available upon request from TDK Innoveta Information furnished by TDK Innoveta is believed to be accurate and reliable However TDK Innoveta assumes no responsibility for its use nor for any infringement of patents or other rights of third parties which may result from its use No license is granted by implication or otherwis...

Отзывы: