Advance Data Sheet: FReta iEB Series –Single Output Eighth Brick Bus Converter

 

©2004-2007  TDK Innoveta Inc.  
 10/29/2007 

 

 (877) 498-0099

 

9/12 

 
Wind Tunnel Test Setup Figure

 

Dimensions are 

in millimeters and (inches). 

 
 
Thermal Management: 

 
An important part of the overall system 
design process is thermal management; 
thermal design must be considered at all 
levels to ensure good reliability and lifetime 
of the final system.  Superior thermal design 
and the ability to operate in severe 
application environments are key elements 
of a robust, reliable power module. 
 
A finite amount of heat must be dissipated 
from the power module to the surrounding 
environment.  This heat is transferred by the 
three modes of heat transfer:  convection, 
conduction and radiation.  While all three 
modes of heat transfer are present in every 
application, convection is the dominant mode 
of heat transfer in most applications.  
However, to ensure adequate cooling and 
proper operation, all three modes should be 
considered in a final system configuration. 
 
The open frame design of the power module 
provides an air path to individual 
components.  This air path improves 
convection cooling to the surrounding 
environment, which reduces areas of heat 
concentration and resulting hot spots. 

 

Test Setup:

 The thermal performance data 

of the power module is based upon 
measurements obtained from a wind tunnel 
test with the setup shown in the wind tunnel 
figure.  This thermal test setup replicates the 
typical thermal environments encountered in 
most modern electronic systems with 
distributed power architectures.  The 
electronic equipment in networking, telecom, 
wireless, and advanced computer systems 
operates in similar environments and utilizes 
vertically mounted PCBs or circuit cards in 
cabinet racks. 
 
The power module, as shown in the figure, is 
mounted on a printed circuit board (PCB) 
and is vertically oriented within the wind 
tunnel.  The cross section of the airflow 
passage is rectangular.  The spacing 
between the top of the module and a parallel 
facing PCB is kept at a constant (0.5 in).  
The power module’s orientation with respect  
 

 
 
to the airflow direction can have a significant 
impact on the module’s thermal 
performance. 
 

Thermal Derating:

 For proper application of 

the power module in a given thermal 
environment, output current derating curves 
are provided as a design 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

guideline on the Thermal Performance 
section for the power module of interest.  
The module temperature should be 
measured in the final system configuration to 
ensure proper thermal management of the 
power module.  For thermal performance 
verification, the module temperature should 
be measured at the component indicated in 
the thermal measurement location figure on 
the thermal performance page for the power 
module of interest.  In all conditions, the  
power module should be operated below the 
maximum operating temperature shown on 
the derating curve.  For improved design 
margins and enhanced system reliability, the 
power module may be operated at 
temperatures below the maximum rated 
operating temperature.

 

 
 

AIRFLOW 

Air Velocity and Ambient 
Temperature 
 Measurement Location

 


O

W

 

12.7 
(0.50)

 

Module 
Centerline

 

Air Passage 
Centerline

 

Adjacent PCB 

76  (3.0) 

Содержание FReta iEB Series

Страница 1: ...converters Standard Features Size 58 4mm x 22 9 mm x 12 3 mm 2 30 in x 0 90 in x 0 485 in Long Thru hole pins 4 57 mm 0 180 High efficiency greater than 94 2250Vdc isolation voltage Meets basic insula...

Страница 2: ...nnoveta Eighth brick FReta 48V nominal 017 17A Amps 120 12V Single 07 Standard Option Table Feature Set Positive Logic On Off Negative Logic On Off 0 180 Pin Length 0 145 Pin Length 00 X X 01 X X 06 X...

Страница 3: ...99 3 12 Mechanical Specification Dimensions are in mm in Unless otherwise specified tolerances are x x 0 5 0 02 x xx and x xxx 0 25 0 010 Recommended Hole Pattern top view Pin Assignment PIN FUNCTION...

Страница 4: ...Io Io max Tc 25 C Output Voltage Rise Time 4 mS Io Io max Tc 25 C Vo 0 1 to 0 9 Vo nom Input Over voltage Turn off 61 Vdc Input rising Input Over voltage Turn on 59 Vdc Input falling Input Over volta...

Страница 5: ...ax Io Io min Vin Vin min 19 5 Vin Vin nom 17 Output Current Vin Vin max 1 16 A At loads less than Io min the module will operate correctly but the output ripple may increase Output Current Limiting Th...

Страница 6: ...vs Input Voltage at Ta 25 degrees 8 9 10 11 12 13 14 0 2 4 6 8 10 12 14 16 18 20 Output Current A Output Voltage V Vin 38V Vin 48V Vin 53V Vin 42V iEB48017A120V 000 Typical Output Voltage vs Load Curr...

Страница 7: ...Output Current Limit Characteristics vs Input Voltage at Ta 25 degrees iEB48017A120V 000 Typical Output Ripple at nominal Input voltage and full load at Ta 25 degrees 0 1 2 3 4 5 6 31 33 35 37 39 41 4...

Страница 8: ...flow from output to input 0 7 0 8 0 9 1 0 1 1 1 2 1 3 35 40 45 50 55 60 Input Voltage V Derating Factor iEB48017A120V 000 thermal measurement location top view iEB48017A120V 000 typical current derati...

Страница 9: ...in most modern electronic systems with distributed power architectures The electronic equipment in networking telecom wireless and advanced computer systems operates in similar environments and utiliz...

Страница 10: ...es may protect themselves by entering a hiccup current limit mode The modules will operate normally once the output current returns to the specified operating range Thermal Protection When the power m...

Страница 11: ...od Improper handling or cleaning processes can adversely affect the appearance testability and reliability of the power modules Contact TDK Innoveta technical support for guidance regarding proper han...

Страница 12: ...met 1 The input source is isolated from the ac mains by reinforced insulation 2 The input terminal pins are not accessible 3 One pole of the input and one pole of the output are grounded or both are k...

Отзывы: