BEFORE USING THE POWER SUPPLY UNIT 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. 
Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. 

 

 

DANGER

 

Never use this product in locations where flammable gas or ignitable substances are present. 

 

  WARNING on USE

 

 

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a burn. 

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

 

For products with no cover, do not touch them as there are high-voltage and high temperature parts inside. Touching them might cause injury 
such as electric shock or burn. 

 

There are cases where high voltage charge remains inside the product immediately after the input is cut off. Therefore, do not touch even if they 
are not in operation as you might get injured due to high voltage and high temperature. 

 

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage the  product. We 
will not be held responsible after the product has been modified, changed or dis-assembled. 

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop using it immediately 
and shut off the product. 

 

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might lead fire and electric 
shock. 

 

Do not drop or apply shock to this product. It might cause failure. Do not operate these products mechanical stress is applied. 

 

When necessary, this products is to be repaired only by us or our authorized agents. 
It  is  important  that  this  product  cannot  be  used  in  hazardous  environments  (facilities  such  as  nuclear  power  control  system  or  life  support 
equipment) without our written consent. 

 

 

CAUTION on MOUNTING

 

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. 

 

Input voltage, Output  current, Output power, ambient  temperature and  ambient humidity  should be kept  within specifications, otherwise the 

product will be damaged. 

 

Input line, please use the wires as short and thick as possible. 

 

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and direct sunlight, or 

places where product is exposed to water or rain. 

 

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be ventilated. 

 

Please shut down the input when connecting input and output of the product. 

 

When installing in environment where conductive foreign, dust and liquid may be present, 

please consider penetration of above foreign material in the power supply by installing filter, to prevent trouble or malfunction. 

 

 

CAUTION on USE

 

 

Product individual notes are shown in the instruction manual. If there is any difference with common notes individual notes shall have priority. 

 

Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the product or fire due 
to improper use. 

 

Input  voltage,  Output  current,  Output  power,  ambient  temperature  and  ambient  humidity  should  be  kept  within  specifications,  otherwise  the 
product will be damaged, or cause electric shock or fire. 

 

If the built-in fuse is blown, do not use the product even after replacing the fuse, as there is risk of abnormality inside. Be sure to request repair 
to our company. 

 

For products without built-in protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke, fire during abnormal operation. 
As for products with built-in protection circuit, depending on usage conditions, built-in protection circuit might not work. It is recommended to 
provide separate proper protection circuit. 

 

For externally mounted fuse do not use other fuses aside from our specified and recommended fuse. 

 

This  product  was  made  for  general  purpose  electronic  equipment  use  and  is  not  designed  for  applications  requiring  high  safety  (such  as 
extremely high reliability  and  safety requirements.    Even  though high reliability  and safety are  not required, this  product  should not be used 
directly for applications that have serious risk for life and physical safety.    Take sufficient consideration in fail-safe design (such as providing 
protective circuit or protective device inside the system, providing redundant circuit to ensure no instability when single device failure occurs). 

 

Содержание ZWS-BP Series

Страница 1: ...perature and ambient humidity should be kept within specifications otherwise the product will be damaged Input line please use the wires as short and thick as possible Do not use this product in speci...

Страница 2: ...t be made accessible to users Protection must be provided for Service Engineers against indirect contact with the output terminals and or to prevent tools being dropped across them While working on th...

Страница 3: ...PUT ZWS240BP COMPONENT SIDE OUTPUT INPUT L ACInputterminal Liveline Fusein line N ACInputterminalNeutral line Earth Terminal Mountinghole holediameter 3 5mm Theseholes are connected to terminal ofCN1...

Страница 4: ...ircuit Active filter 65kHz fixed Fuse rating ZWS150BP 6 3A ZWS240BP 10A Inrush Current Limit Circuit Rectifier Filter Switching Circuit L N Control Circuit OCP Circuit OVP Sensing Output Sensing Photo...

Страница 5: ...k current condition Operating time at peak output is less than 5 sec duty is less than 40 When the Product operate peak Current for more than 5 sec the delay shut down function operates and the output...

Страница 6: ...ctor Useinput outputconnector housing specified by thetablebelow Use recommended crimping tool Connectorisnotincluded with thisproduct Referto the following ZWS150BP COMPONENT SIDE OUTPUT INPUT LOAD Z...

Страница 7: ...down To reset delay shut down remove the input of power supply for a few minutes and then re input Delay Shut Down Time value is fixed and not to be adjusted externally Use it about the peak electric...

Страница 8: ...use as Back up Power Supply 1 Adjust the output voltage of each power supply to be the same 2 Set power supply output voltage higher by the forward voltage drop Vf of diode Use within the specificati...

Страница 9: ...withstand voltagetester maygeneratehigh voltage atthe matching with monolithic ceramic capacitor and may causetheunitdamage So pleasecheckthe waveformofapplied voltage Note 2 In case of using externa...

Страница 10: ...ondary output side of the power supply unit Do not connect in the Primary input side And this circuit is isolated from the Secondary output The standby power in control OFF is 100VAC input 0 15W typ 2...

Страница 11: ...e output will shut down Peak output power and average output power use less than specification Peak output power is limited depending on Duty The details see at b The product might be damage to use be...

Страница 12: ...3 30 32 10 28 10 70 100 100 100 82 Mounting D F FORCED AIR COOLING ZWS150BP ZWS240BP Electrolytic capacitor allowable Max temparature Mounting A F Mounting A F ZWS150BP C7 Model Allowable Max temparat...

Страница 13: ...ift the unit And use all mounting holes A for the unit installation The vibration spec is specified under this mounting condition Please use mounting hole B as needed Vibratility resistant improves Mo...

Страница 14: ...be separated each other and twisted individually to improve noise 2 Use all lines as thick and short as possible to made lower impedance 3 Noise can be reduced by attaching a capacitor to the load te...

Страница 15: ...that the unit is at fault 1 Check if the rated input voltage is connected 2 Check if the wiring of input and output is correct 3 Check if the wire thickness is enough 4 Check if the output current and...