background image

INSTRUCTION MANUAL

ZWS300RC 

Series

TDK-Lambda

<Page>

(2) Condition to meet Isolation & Withstand Voltage standard

    

    keep 4mm space from the top and sides of power supply.

    

    And keep 8mm space from the solder surface of PCB.

(3)

              

must be connected to the Protective earth terminal of the equipment. Also 2 mounting holes are must be

    

    connected to the Chassis (Conductor) by Metal spacer. When screw clamping the mounting holes, please

    

    use the screw with spring washer. If not connect to the Chassis (Conductor), the conducted noise, radiation

    

    noise and output noise will increase. (The location of 2 mounting holes for Chassis connection is shown

    

    with 

       

mark in below figure.)

8. Wiring Method

(1) The output load line and input line shall be separated, and use all lines as thick and short as possible to make 

   lower impedance. The output load line and input line shall be twisted or use shielded wire to improve noise 
   sensitivity.

(2) Input/Output lines shall be twisted and separated from the output lines.
(3) Noise can be eliminated by attaching a capacitor to the load terminals.
(4) For safety and EMI considerations, connect between      terminal of input connector and protective earth terminal

   firmly. 

(5) The recommended wire type, torque and crimp-type terminal :

Input      

:  

AWG#22  ~  AWG#18

Output

 

 

:  

AWG#22  ~  AWG#16

16/17

M

or

th

an

 

4m

m

M

or

th

an

 

8m

m

PCB

Component side

M

or

th

an

 

4m

m

More than 

4mm

More than 

4mm

Chassis (Conductor)

N

L

Metal spacers

Wire

Input

Output

+

-

Protective

earth terminal

-V  +V

M

or

th

an

 

4m

m

Содержание ZWS 300 RC-24

Страница 1: ...not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc Please stop using it immediately and shut off the product It might lead to fire and electric sho...

Страница 2: ...r or dust there is possibility of product failure or malfunction Provide countermeasure for prevention of lightning surge voltage noise and static electricity as there is risk of damage due to abnorma...

Страница 3: ...ock or mechanical stress applied directly to the product Please keep away from direct sunlight For long term storage temperature and humidity the following conditions shall be used as a guideline Temp...

Страница 4: ...diameter 3 5mm These holes are connected to terminal of CN1 Must be connected to Chassis Conductor of the equipment by electrically conductive spacer Mounting hole hole diameter 3 5mm These holes are...

Страница 5: ...Hz 70kHz Spread Fuse rating 6 3A 5 17 Line Filter Rectifier Circuit PFHC Circuit Inrush Current Limit Circuit Filter Circuit Switching Circuit Control Circuit L N Control Circuit OCP Circuit OVP Circu...

Страница 6: ...er than 4 5V Output on Lower than 0 8V Output off This sequence is using external voltage 2 OVP detection point 115 135 6 17 0V Vout H 0V L Input Voltage Output Voltage Remote ON OFF Control R R Level...

Страница 7: ...product Use the terminal pin SVH 21T P1 1 or BVH 21T P1 1 when output current per connector pin is 5A or less Use the terminal pin SVH 41T P1 1 or BVH 41T P1 1 when output current per connector pin i...

Страница 8: ...and then re input Please turn the trimmer slowly during the output voltage adjustment 6 3 Inrush Current Inrush current is suppressed by power thermistor for the product Higher current will flow at h...

Страница 9: ...ripple cannot be measured accurately if the probe ground lead of oscilloscope is too long 6 7 Series Operation For series operation either method A or B is possible Never use when one of the unit not...

Страница 10: ...ns 4 When using RP 60 20 output load current should be used within specifications When using ORing diode current rating must be more than output load current A B 6 9 Isolation Test Isolation resistanc...

Страница 11: ...nd voltage please add external capacitor to Output and terminal It can decrease the voltage On the other hand no need to check the voltage in case of Output and terminal is shorted The example of nois...

Страница 12: ...ction manual ZBM AC connectable quantity ZBM AC connection example Output power vs Hold up time characteristics ZWS300C Input Voltage 200VAC Ta 25 Initial state of capacitor capacity 12 17 0 50 100 15...

Страница 13: ...the output derating below load is percent of maximum output current value in a rated output voltage Convection Cooling 85 Vin 170VAC or 120 Vin 240VDC Derating is required for less than 90VAC or less...

Страница 14: ...45 100 85 88 55 75 50 100 77 77 46 70 60 65 53 53 28 40 70 30 30 30 10 10 Ta C Load Air velocity 0 7m s Air velocity 1 4m s Load Load MOUNTINGA E MOUNTINGA E 10 50 100 10 60 100 70 60 70 70 Ta C Ta C...

Страница 15: ...able area by metal pieces is 9mm from each PCB corners Refer to figure below If the space is not enough the specification of isolation and withstand will not be satisfied Take the space in the product...

Страница 16: ...rk in below figure 8 Wiring Method 1 The output load line and input line shall be separated and use all lines as thick and short as possible to make lower impedance The output load line and input line...

Страница 17: ...is at fault Before concluding that the product is at fault make the following checks 1 Check if the rated input voltage is connected 2 Check if the wiring of input and output is correct 3 Check if th...