TDK-Lambda SWS-L Series Скачать руководство пользователя страница 8

8

・All specifications are subject to change without notice.

Block Diagram

L

FG

N

INPUT
85

265VAC

CNT1

AUX

TRANSFORMER

CURRENT
SHARING
CIRCUIT

VOLTAGE
ADJUST

REMOTE
CONTROL

OVP
SENSING

OCP
CIRCUIT

OVP
CIRCUIT

CONTROL
CIRCUIT

RECTIFIER
AND
SMOOTHING
FILTER

MAIN

TRANSFORMER

SWITCHING
CIRCUIT

CURRENT
SENSING

CONTROL
CIRCUIT

SMOOTHING
FILTER

INRUSH
CURRENT
LIMIT
CIRCUIT

G2

G2

AUX

AUX

SECONDARY

PRIMARY

G1

COM

COM

COM

CNT2
TOG

NC

PV

+S

ALM

PC

-S

+Vm

 -Vm

-V

+V

OUTPUT

ALARM

FAN

PFC
CIRCUIT

RECTIFIER

LINE
FILTER

Sequence Time Chart

SWS1000L

* INPUT VOLTAGE RANGE : 85

265VAC

* FUSE RATING : 20A

* PFC FREQUENCY : 130kHz  BOOST MODE

* DC-DC FREQUENCY : 200kHZ  FORWARD

SWS600L

* INPUT VOLTAGE RANGE : 85

265VAC

* FUSE RATING : 15A

* PFC FREQUENCY : 100kHz  BOOST MODE

* DC-DC FREQUENCY : 300kHz  FORWARD

AC Input

Output voltage
(DC-DC Converter)

REMOTE
ON/OFF

ALM

Vout

0V

H(ALM)

H(CNT)

L(G1)

L(TOG)

INPUT ON

REMOVE
    OFF

REMOVE

ON

OVP

INPUT

OFF

INPUT

ON

INPUT

OFF

INPUT

OFF

INPUT

ON

OCP

OCP

DISABLE

FAN

STOP

OTP,

CONVERTER

FAILURE

SWS 

600L, 1000L

Содержание SWS-L Series

Страница 1: ...SWS L Series Compact and high power AC DC power supply...

Страница 2: ...All specifications are subject to change without notice...

Страница 3: ...Lambda always provides our customers with the best power solutions by combining extensive industry market research with our advanced R D expertise ensuring that our power supplies will continue to evo...

Страница 4: ...lation Withstand Voltage Input Output 3 0kVAC 20mA Input FG 2 0kVAC 20mA Output FG 500VAC 100mA 60V model 651VAC 130mA Output CNT ALM AUX 100VAC 100mA for 1min Isolation Resistance Input FG Input Outp...

Страница 5: ...VOLTAGE RANGE NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AND PEAK OUTPUT CURRENT ARE SHOWN ON THE NAME PLATE IN ACCORDANCE WITH THE SPECIFICATIONS 2 COUNTRY OF MANUFACTURE IS SHOWN ON THE NAME PLA...

Страница 6: ...Ta 25 C first inrush second inrush Leakage Current typ 11 mA 0 1mA at 115VAC 60Hz 0 2mA at 230VAC 60Hz Output Nominal Voltage VDC 3 3 5 12 15 24 36 48 60 Maximum Current Peak Current 1 A 200 88 70 44...

Страница 7: ...2 5 37 MAX 29 AIR FLOW 165 0 5 240 1 3 MAX BOTTOM SIDE SEE NOTE C 150 1 110 0 5 20 FG FG L N 38 0 5 4 M4 2 9 10 10 20 2 1 23 1 17 9 29 165 0 5 BOTH SIDES SEE NOTE C 61 1 11 5 CN2 CN3 LED CN1 AMBDA L A...

Страница 8: ...ARY G1 COM COM COM CNT2 TOG NC PV S ALM PC S Vm Vm V V OUTPUT ALARM FAN PFC CIRCUIT RECTIFIER LINE FILTER Sequence Time Chart SWS1000L INPUT VOLTAGE RANGE 85 265VAC FUSE RATING 20A PFC FREQUENCY 130kH...

Страница 9: ...azardous voltage These terminals must not be user and service person accessible This power supply is capable of providing hazardous energy output 240VA the end equipment manuafacturer must provide pro...

Страница 10: ...and function They are connected to each other in this power supply unit When the pin of CN1 side is shorted the same function pins of CN2 side are also shorted Please note that the function cannot be...

Страница 11: ...load line Output current of each terminal screw shall be 60A or less for SWS600L Panel Side Basic connection Local sensing Connect S terminal to Vm terminal and S terminal to Vm terminal SWS600L SWS10...

Страница 12: ...ure Detection Circuit ALM Power failure detection circuit is provided ALM Alarm signal will turn High level to indicate the abnormal status when con verter stops Please take note in parallel or N 1 op...

Страница 13: ...hort as possible and same length and twisted 1 Adjust the output voltage of each power supply to be same value within 1 or 100mV whichever is smaller 2 Use same length and type of wires for all load l...

Страница 14: ...each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 20mA Output chassis and Output Control 100mA The applied voltage must be gradually increased f...

Страница 15: ...ut Peak Current For 24V 48V output model please meet the following condi tions Reduce peak current value according to output derating as section 4 2 Input voltage range AC170V 265V Continuous Peak out...

Страница 16: ...This power supply has ventilating holes on the front and back side panels Keep these two areas freely as much as possible 2 The maximum allowable penetration for screw is 6mm Incomplete thread of moun...

Страница 17: ...m Type Size Conductor part Insulation part UL1007 AWG 28 1 2 0 55 0 60 1 6 UL1007 AWG 26 1 3 0 60 0 65 1 7 UL1007 AWG 24 1 5 0 62 0 67 1 8 Note1 Crimp height at wire barrel should be set to pre determ...

Страница 18: ...ent temperature 9 Special instructions for IEC EN UL CSA 60601 1 SWS1000L only 1 These products are designed for continuous operation within an overall enclosure and must be mounted such that access t...

Страница 19: ...f use function of the Remote ON OFF control check if the Remote ON OFF control is properly used 7 Check if the built in FAN is not stopped Is FAN stopped by something irregular or etc If FAN stops the...

Страница 20: ...Each Manufacturing Company This datasheet has been downloaded from www EEworld com cn Free Download Daily Updated Database 100 Free Datasheet Search Site 100 Free IC Replacement Search Site Convenien...

Отзывы: