INSTRUCTION MANUAL
RWS1000B
•
1500B Series
TDKLambda
<Page>
/FO, /RFO
CN83, CN84 : Remote sensing, PF signal, Parallel operation setup
Remote ON/OFF control (Only /RFO)
* CN83, CN84 Connector (JST)
Each other terminals are same as standard model.
"+Vm" terminal (Pin No.1) to "+S" terminal (Pin No.2), and "Vm" terminal (Pin No.9) to "S" terminal
(Pin No.10) are connected by short pieces (connected to CN83) at time of shipment.
/R
CN83, CN84 : Remote ON/OFF control
* CN83, CN84 Connector (JST)
Each other terminals are same as standard model.
"+Vm" terminal (Pin No.1) to "+S" terminal (Pin No.2), and "Vm" terminal (Pin No.9) to "S" terminal
(Pin No.10) are connected by short pieces (connected to CN83) at time of shipment.
5/19
10
9
7
5
3
1
8
6
4
2
10
CN83,CN84
10
No. Configuration
Function
1
+Vm
Output monitor terminal (+V). Internally connected to +Output terminal.
(+Vm terminal can not supply load current.)
2
+S
Remote sensing terminal for +output.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to +Vm terminal when
remote sensing function unnecessary.)
3
+R
Remote ON/OFF control terminal (Only /RFO). Do not connect for /FO. If
connected may cause malfunction.
4
R
GND for Remote ON/OFF control terminal (Only /RFO). Do not connect
for /FO. If connected may cause malfunction.
5
+PF
Power fail signal (PF signal) output terminal.
(Open collector output. As the output voltage drops or FAN stop and AC
input voltage down, "PF" signal will be "High".)
6
PF
GND for PF signal.
7
COM
Current barance terminal. (For current balancing in parallel operation.)
8
PC
Current barance terminal. (For current balancing in parallel operation.)
9
Vm
GND for Output monitor terminal. Internally connected to Output
terminal.
( Vm terminal can not supply load current.)
10
S
Remote sensing terminal for output side.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to Vm terminal when
remote sensing function unnecessary.)
No. Configuration
Function
1
+Vm
Output monitor terminal (+V). Internally connected to +Output terminal.
(+Vm terminal can not supply load current.)
2
+S
Remote sensing terminal for +output.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to +Vm terminal when
remote sensing function unnecessary.)
3
+R
Remote ON/OFF control terminal.
4
R
GND for Remote ON/OFF control terminal.
5
NC
No cnnection
6
NC
No cnnection
7
NC
Do not connect. If connected may cause malfunction.
8
NC
No cnnection
9
Vm
GND for Output monitor terminal. Internally connected to Output
terminal. ( Vm terminal can not supply load current.)
10
S
Remote sensing terminal for output side.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to Vm terminal when
remote sensing function unnecessary.)
9
7
5
3
1
8
6
4
2
10
CN83,CN84