17814 issue 16, October 2018 

 

 

 

 

 

 

 

 

 

    

    

 

NVM175 Handbook

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH 

General Safety Instructions: 

READ SAFETY INSTRUCTIONS     

 

Servicing: 

These products are not customer serviceable.  TDK-Lambda UK LTD. and their authorised agents only are 

permitted to carry out repairs.  

 
Critical Components: 

These products are not authorised for use as critical components in nuclear control systems, life support 

systems or equipment for use in hazardous environments without the express written approval of the 

Managing Director of TDK-Lambda EMEA. 

 
Product Usage: 

These products are designed for use within a host equipment which restricts access to authorised competent 

personnel. 

 

This product is a component power supply and is only to be installed by qualified persons within other 

equipment and must not be operated as a stand alone product. 

This product is for sale to business to business customers and can be obtained via distribution channels.  

It is not intended for sale to end users. 

 

This product is a component power supply and does not fall within the scope of the EMC directive. 

Compliance with the EMC directive must be considered in the final installation. Please contact your local 

TDK-Lambda office. 

 

Environmental: 

These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be 

used. 

 
Environment: 

This power supply is a switch mode power supply for use in applications within a Pollution Degree 2, 

overvoltage category II environment. Material Group IIIb PCB’s are used within it. 

 

Output Loading: 

The output power taken from the power supply must not exceed the rating stated on the power supply label, 

except as stated in the product limitations in this handbook. 

 

Input Parameters: 

This product must be operated within the input parameters stated in the product limitations in this handbook. 

 

End of Life Disposal: 

The unit contains components that require special disposal. Make sure that the unit is properly disposed of at 

the end of its service life and in accordance with local regulations. 

 

RISK OF ELECTRIC SHOCK           

 

High Voltage Warning: 

Dangerous voltages are present within the power supply

.  

The professional installer must protect service 

personnel from inadvertent contact with these dangerous voltages in the end equipment. 

 

 

WARNING

: When installed in a Class 1 end equipment, this product must be reliably earthed and 

professionally installed. 

 

When installed in a Class II end equipment, no earthing connection to the power supply is required. 

 

 

Содержание NVM175

Страница 1: ...stallation Please contact your local TDK Lambda office Environmental These products are IPX0 and therefore chemicals solvents cleaning agents and other liquids must not be used Environment This power...

Страница 2: ...be reliably earthed and professionally installed in accordance with the prevailing electrical wiring regulations and the safety standards covered herein A suitable mechanical electrical and fire enclo...

Страница 3: ...rmit t mit der EMV Richtlinie muss in der finalen Gesamtinstallation betrachtet werden Bitte kontaktieren Sie Ihr regionales TDK Lambda Vertriebsb ro im Falle von R ckfragen Umwelt Diese Produkte sind...

Страница 4: ...t an TDK Lambda UK LTD oder einen der autorisierten Vertriebsh ndler zur ckgeschickt werden Ein geeignetes mechanisches elektrisches und brandgesch tztes Geh use muss als Schutz vor der Gefahr von me...

Страница 5: ...r votre bureau TDK Lambda le plus proche Environnement Ces produits sont IPX0 et donc on ne doit pas utiliser des produits chimiques solvants des produits de nettoyage et d autres liquides Environneme...

Страница 6: ...tre remplac par l utilisateur En cas de d faut interne le module doit tre renvoy TDK Lambda UK LTD ou l un de ses agents agr s Une enceinte appropri e doit tre pr vue par l utilisateur final pour assu...

Страница 7: ...no a vostra disposizione per ulteriori ragguagli Condizioni ambientali Questi prodotti sono classificati come IPX0 dunque non devono essere utilizzati sostanze chimiche solventi prodotti per la pulizi...

Страница 8: ...TDK Lambda UK LTD o a uno dei suoi agenti autorizzati L apparecchiatura finale deve includere una recinzione meccanica elettrica e antincendio per proteggere dai pericoli di natura meccanica dalle sco...

Страница 9: ...Este producto es una fuente de alimentaci n y no se ve afectada por la directiva EMC El cumplimiento de la directiva EMC se debe considerar en la instalaci n final Por favor p ngase en contacto con s...

Страница 10: ...ice tornillos de montaje susceptibles de penetrar en la unidad m s de 4 5 mm Un fusible interno protege la unidad y este no debe ser nunca reemplazado por el usuario En caso de existir alg n defecto i...

Страница 11: ...rectiva CEM Conformidade com a directiva CEM devem ser considerados na instala o final Entre em contacto com seu escrit rio TDK Lambda mais pr ximo Ambiental Estes produtos s o IPX0 e como tal n o se...

Страница 12: ...ser devolvida TDK Lambda UK LTD ou a um dos seus agentes autorizados AVISO Estes produtos pertencem Classe 1 devendo assim ser ligados terra de forma fi vel e instalado por profissionais de acordo com...

Страница 13: ...otected against the ingress of water All outputs have basic spacings to earth rated for mains at 250Vac and due consideration must be given to this in the end product design These products have SELV o...

Страница 14: ...s please contact our sales team for details Unit Nomenclature NVM175 or NVM 175 models as described below Units may be marked with a Product Code X5x or NVM1x where x may be any number of characters U...

Страница 15: ...nd non standard models with output parameters shown in the tables below Output channel Voltage designation Vout V nom Adjustment range V Output current A Maximum power W Channel 1 T 12 12 15 5 15 180...

Страница 16: ...e end use equipment handbook specification and which will result in the highest temperatures in the PSU To determine the most adverse conditions consideration should be given to the end use equipment...

Страница 17: ...Page 17 of 23 17814 issue 16 October 2018 NVM175 Handbook COMPONENTS TO BE MONITORED DIAGRAMS Main PCB...

Страница 18: ...Page 18 of 23 17814 issue 16 October 2018 NVM175 Handbook Control PCB...

Страница 19: ...Page 19 of 23 17814 issue 16 October 2018 NVM175 Handbook NVM175 Vertical Connector Outline and Connections NVM175 Right Angle Connector Outline and Connections...

Страница 20: ...17814 issue 16 October 2018 NVM175 Handbook NVM175 Vertical Connector With Optional Case And Cover C Option NOTES 1 ALL CUSTOMER FIXINGS M3 MAXIMUM PENETRATION 4 5mm MAXIMUM TORQUE 0 5 0 6Nm 2 ALL TOL...

Страница 21: ...Page 21 of 23 17814 issue 16 October 2018 NVM175 Handbook NVM175 K Option chassis...

Страница 22: ...Page 22 of 23 17814 issue 16 October 2018 NVM175 Handbook NVM1D with 18 way output connector which may be upright or right angled only upright version shown...

Страница 23: ...175 Handbook NVM175 Screw Terminal S Option TDK Lambda UK Ltd Kingsley Avenue Ilfracombe Devon EX34 8ES Telephone Sales and Service 44 0 1271 856666 Head Office and Works 44 0 1271 856600 Facsimile 44...

Отзывы: