83-517-000 Rev.
A
57
6.6
REMOTE MONITORING OF OUTPUT VOLTAGE AND CURRENT
The J1 connector, located on the rear panel provides analog signals for monitoring the Output voltage and
Output current. Selection of the voltage range between 0-5V and 0-10V is made by setup DIP-switch SW1-4.
The monitoring signals represent 0 to 100% of the power supply Output voltage and Output current. The monitor
outputs have an output resistance of 500 ohms. Ensure that the sensing circuit has an input resistance of
greater than 500kohms or accuracy will be reduced.
Refer to Table 6-5 for the required J1 connection, SW1-4 setting and monitoring voltage range.
Signal
Name
Signal
Function
J1 connection
Range
SW1-4
Signal (+)
Return (-)
VMON
Vout Monitor
J1-11
J1-12
0-5V
Down
IMON
Iout Monitor
J1-24
VMON
Vout Monitor
J1-11
J1-12
0-10V
Up
IMON
Iout Monitor
J1-24
Table 6-5 Monitoring Signals Settings (Vout/Iout)
Notes:
1.
Radiated Emissions, FCC requirements
:
FCC requirements for radiated emissions: Use a shielded cable
for the analog control signals If using an unshielded cable,
attach an EMI ferrite suppressor to the cable, as close as
possible to the power supply.
2.
Front Panel Encoders Operation
:
In remote analog mode, the Output voltage and Output current
can’t be set by the
VOLTAGE
and
CURRENT
encoders.
3.
Front Panel PREView
Button
:
Use the
PREV
iew button to display the Output voltage and
Output current setting defined by the encoders or digital
communication.
4.
Communication
:
In Remote
Analog
mode, all power supply parameters can be
programmed and read back via the serial (RS-232/RS-485)
communication port, except the Output voltage and Output
current setting (which can only be read back).