83-517-000 Rev.
A
46
5.8
ENABLE/DISABLE CONTROL VIA REAR PANEL J1 CONNECTOR
Contacts J1-1 and -14 (Figure 4-2, Item 5) serve as Output Enable/Disable terminals (by switch or relay). This
function is Enabled or Disabled by Dip-switch SW1-9. Refer to Table 5-3 for the Enable/Disable function and the
SW1 setting.
SW1-9 setting
Enable/Disable Inputs
Power supply output
Display
ALARM LED
DOWN
(Default)
Open or Short
ON
Voltage/Current
OFF
UP
Open
OFF
“
ENA
”
Blinking
Short
ON
Voltage/Current
OFF
Table 5-3: Enable/Disable Function and SW1 Setting
5.9
CV/CC SIGNAL
The
CV/CC
signal indicates the operating mode of the power supply, Constant-Voltage or Constant-Current. The
CV/CC
signal is an open collector output with a 30V parallel zener diode, at J1-13, referenced to the
COM
potential at J1-12 (connected internally to the negative sense
(-S)
potential). When the power supply operates in
Constant-Voltage mode, the
CV/CC
output is open-circuit. When the power supply operates in Constant-Current
mode, the
CV/CC
signal output is low (0.0 - 0.6V) with a maximum sink current of 10mA.
5.10
PS_OK SIGNAL
The
PS_OK
signal indicates a fault condition in the power supply.
PS_OK
is a TTL signal output at J1-16 and is
referenced to
IF_COM
at J1-2, -3 (Isolated Interface Common). When a fault condition occurs, the
PS_OK
level
is low, with a maximum sink current of 1mA. When no fault condition occurs, the
PS_OK
level is high with a
maximum source current of 2mA. The following faults will set the
PS_OK
to a fault state:
OTP
Enable/Disable open (Power supply is disabled)
OVP
SO
(Rear panel Shut-Off, Power Supply is shut off)
FOLD
back
IEEE failure (With optional IEEE interface)
AC
fail
Output
OFF
NOTE
Safe-Start mode
: If the Enable/Disable fault condition clears when the unit is in Safe-Start
mode, recovery is made by pressing the
OUT
button or by sending an ‘
OUT 1
’ serial
command.
Auto-Restart
mode
: The output will turn back
ON
automatically when the Enable/Disable
fault condition clears.
CAUTION
Do not connect the
CV/CC
signal to a voltage source higher than 30VDC. Always
connect the CV/CC signal to voltage source with a series resistor to limit the sink
current to less than 10mA.
CAUTION
To prevent possible damage to the unit, do not connect any of the Enable/Disable
inputs to the positive (+V) or negative (-V) output potential.