FPS1000 SAFETY INSTRUCTIONS

SAFETY APPROVALS

UL 60950-1 and CSA22.2 No.60950-1 - UL Recognized. C-UL for Canada.

IEC 60950-1 - CB Report and Certificate.

EN 60950-1 - CE mark.

Marking by the CE Symbol indicates compliance to the Low Voltage Directive of the European Union.

A “Declaration of Conformity” in accordance with the preceding directives and standards has been made and is on file at our EU 

representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
A “Declaration of Conformity” may be accessed via company website www.uk.tdk-lambda.com/technical-data

CAUTION:

 The following safety precaution must be observed during all phases of operation, service and repair of this equipment. 

Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and 

intended use of this equipment and may impair the built-in protections within. TDK Lambda shall not be liable for user’s failure to 

comply with these requirements.

Vorsicht:

 Die folgenden Sicherheitsvorschriften müssen vor Inbetriebnahme und in jedem Betriebszustand bei Service oder 

Reparatur beachtet werden. Missachtung der Sicherheitsvorschriften und Warnhinweise aus diesem Handbuch führen zur 
Verletzung der bestehenden Sicherheitsstandards. Bei Betrieb des Gerätes ausserhalb dem bestimmungsgemässen Einsatz 
können die im Gerät integrierten Schutzfunktionen beeinträchtigt werden. TDK-Lambda ist nicht haftbar für Schäden, die durch 
Missachtung dieser Sicherheitsvorschriften entstehen können.

CAUTION: FPS1000 units are not authorized for use as critical component in nuclear control systems, life support systems or

equipment for use in hazardous environments without the express written approval of the managing director of TDK-Lambda.

Vorsicht:

 Dieses Produkt ist nicht für die Verwendung als kritische Komponente in nuklearen Steuerungssystemen, 

lebenserhaltenden Systemen oder Geräte für den Einsatz in gefährlichen Umgebungen, ohne die ausdrückliche schriftliche 
Genehmigung durch TDK-Lambda zugelassen.

INSTALLATION (OVERVOLTAGE) CATEGORY& ENVIRONMENTAL CONDITIONS

The FPS1000 units have been evaluated to Overvoltage category II.

The FPS1000 units intended for use in the following operation conditions:

* Indoor use * Pollution degree 2 * Max. operational altitude: 3000m above sea level

*Ambient temperature: -10°C-50°C at 100% load, up to 70°C with output de-rating applied (See Specification)

GROUNDING

FPS1000 units are Class I product. To minimize electrical shock hazard, the FPS1000 units must be connected to an electrical ground. 

The instruments must be connected to the AC power supply mains through a three conductor power cable, with the ground wire 

firmly connected to an electrical ground (safety ground) at the power outlet. For instruments designed to be hard-wired to the supply 

mains, the protective earth terminal must be connected to the safety electrical ground before any other connection is made. Any 

interruption of the protective ground conductor or disconnection of the protective earth terminal will cause a potential shock hazard 

that might cause personal injury.

Erdungskonzept:

 Dieses Produkt ist ein Gerät der Schutzklasse 1. Zur Vermeidung von gefährlichen Energieinhalten und 

Spannungen, ist das Gehäuse an eine Schutzerde anzuschliessen. Der PE-Anschluss ist an einen festen Erder anzuschliessen. Bei 
Festverdrahtung des Gerätes ist sicherzustellen, dass der PE Anschluss als erstes angeklemmt wird Jede mögliche Unterbrechung 
des PE-Leiters oder Trennung der PE Verbindung kann einen möglichen elektrischen Schlag hervorrufen, der Personenschäden zur 
Folge hätte.

LIVE CIRCUITS

Operating personnel must not remove the FPS1000 units cover. No internal adjustment or component replacement is allowed by non-

TDK Lambda qualified service personnel. Never replace components with power cable connected. To avoid injuries, always disconnect 

power, discharge circuits and remove external voltage sources before touching components. Restricted Access Area: FPS1000 units 

should only be installed in a Restricted Access Area. Access should be available to service personnel only

Spannungsführende Teile

Die Geräteabdeckung darf nicht durch Endanwender geöffnet werden. Interne Modifikationen, sowie Bauteileaustausch ist nur 

durch TDK-Lambda qualifiziertes Personal erlaubt. Vor Austausch von Bauteilen ist das Netzkabel bzw. die Versorgungsspannung 

zu trennen. Energieversorgungsanschlüsse sind immer zu trennen, um Personenschäden durch gefährliche Energieinhalte und 

Spannungen auszuschliessen. Die Stromkreise sind zu entladen, externe Spannungsquellen sind zu entfernen, bevor auf Bauteile bzw. 

Komponenten Ebene gearbeitet wird.

Содержание FPS1000 Series

Страница 1: ...Maximum output current Vout voltage trimming Front panel indicators I 2 C Interface Operating temperature models without IEC inlet models with IEC inlet Possible via Vout Trim pin in the I O connector Refer to Instruction Manual AC OK DC OK DC FAIL Optional Refer to Instruction Manual 0 50 C 100 load Derate 2 C 50 C to 60 C Derate 2 5 C 60 C to 70 C Storage temperature Operating humidity Storage h...

Страница 2: ......

Страница 3: ......

Страница 4: ...conditions Indoor use Pollution degree 2 Max operational altitude 3000m above sea level Ambient temperature 10 C 50 C at 100 load up to 70 C with output de rating applied See Specification GROUNDING FPS1000 units are Class I product To minimize electrical shock hazard the FPS1000 units must be connected to an electrical ground The instruments must be connected to the AC power supply mains through ...

Страница 5: ...sons the mains supply voltage fluctuations should not exceed 10 of nominal voltage ENERGY HAZARD The main output of FPS1000 units is capable of providing hazardous energy Due to hazardous energy level the output and connections therefore must not be user accessible Manufacturer s final equipment must provide protection to service personnel against inadvertent contact with output bus bars FUSE Inte...

Страница 6: ......

Страница 7: ...e 1 1 4 Supervisory signals 1 3 On off control Fig 1 3 ON OFF FPS1000 ON OFF 7 SIGNAL_RTN 10 1 2 Output voltage trimming FPS1000 S V_TRIM S 8 14 13 R1 R2 FPS1000 12V AUX AC_FAIL DC_OK TEMP ALARM SIGNAL_RTN Application Monitoring and Control circuts 10K 10K 10K Fig 1 4 16 11 9 12 10 V V In Local sense applications the sense have to be connected to the V terminals of the FPS1000 units prior the oper...

Страница 8: ... CS SIG RTN ON OFF CS FPS1000 N SIG RTN ON OFF CS FPS1000 2 V TRIM S S V TRIM S S V TRIM V TRIM S S R1 R2 7 10 7 10 7 10 15 15 15 Derate the totaloutputcurrent by 10 when using parallel operation to prevent overload condition The built in Oring diodes on the main output and the 12V Auxiliary output allow N 1 operation For input voltages less than 100Vac maximum outputPower derated by 10 of the Pow...

Страница 9: ...S S V 7 10 7 10 Up to 3 units can be used for increased output voltage It is recommended that diodes be connected in parallel with each unit output to prevent revese voltage Each diode should be rated to at least the power supply rated output voltage and output current Fig 3 1 ON OFF FPS1000 1 SIG RETURN ON OFF FPS1000 2 SIG RETURN ON OFF FPS1000 N SIG RETURN ON OFF 7 10 7 10 7 10 Fig 2 3 CAUTION ...

Страница 10: ... obsruct air flow to the unit front panel 2 Mounting screws must not penetrate more than 3mm into the unit Fig 5 1 More than 50mm More than 50mm 3 mounting holes M3 Marked A see note 2 Air flow direction Front side see note 1 1 AC OK Green LED On when input voltage 85Vac Off when Input voltage 85Vac 2 DC OK Green LED On when output voltage Vout 80 5 of Vo rated Off when output voltage Vout 80 5 of V...

Страница 11: ...25 x 8 200 pF 50pF 250pF Input voltage 85Vac 80 5 of Vo rated For minimum pullup resistor selection use the following equation VDD in FPS is 5V VOL max is 0 4V IOL is 3mA So RP min is 1 53 kOhm Each of the 3 ICs adds some capacitance to the bus The total capacitance generated by the 3 ICs in each power supply is about 25pF Considering about 50pF extra capacitance for parasitic capacitance wire cap...

Страница 12: ...Vout 206 0 2344 48 286V FPS1000 24 S A D so that on every read data from each channel is read Note that on each read a conversion is started for a particular channel and the result which will be displayed and will be of the previous read i e the previous channel Thus second read cycle gives result of the actual channel Note the first result from a sequence of reads should not be considered FPS1000...