INSTRUCTION MANUAL
EVS300W/600W
Series
TDKLambda
<Page>
1. Model name identification method
EVS 18
–
16R7 /
□
(*1)
EVS300W,EVS600W common options
Blank : Standard
/R
: With remote ON/OFF control model.
EVS300W only
/A
: With chassis and cover model.
/RA : With chassis and cover and Remote
ON/OFF control model.
2. Terminal Explanation
■
EVS300W
L : Input terminal (Live line) (M4 screw)
(Fuse in line)
N : Input terminal (Neutral line) (M4 screw)
: Earth terminal (M4 screw)
Mounting hole (hole diameter :
φ
3.5mm)
These holes are connected to terminal of TB1.
Must be connected to electrically conductive spacer. The mounting surface of the spacer should be within Max
φ
8mm.
Mounting hole (hole diameter :
φ
3.5mm)
These holes are not connected to
terminal of TB1.
+
: + Output terminal (M4 screw)
-
: Output terminal (M4 screw)
V.ADJ : Output voltage adjustment trimmer. The output voltage rises when a trimmer is turned clockwise.
Remote ON/OFF control terminal (Option
“
/R
”
,
“
/RA
”
)
I.ADJ : Output constant current adjustment rotary switch
(Refer to
“
47. Output Constant Current Adjustment Method
”
for usage)
This adjustment trimmer is for factory setting only. Do not touch this trimmer.
EVS300W Option /R , /RA
*Remote ON/OFF control terminal
:
Option
“
/R
”
,
“
/RA
”
Hand Crimping Tool
:
YC110R
(
JST
)
or YRS110
(
JST
)
Use maker recommended crimping tool.
Housing and terminal pin are not included in the product.
3/22
1
2
3
9
8
7
6
5
4
10
11
Ref.No.
Connector
Housing
Terminal Pin
Maker
JST
B2BXHAM
XHP2
BXH001TP0.6
or
SXH001TP0.6
CN52
Input
Output
1
2
3
4
5
5
5
8
9
6
7
4
11 10
TB1
TB51
CN52
VR51
S1
VR1
Component side
Option (*1)
Rated Output Current
Rated Output Voltage
Series Name