background image

INSTRUCTION MANUAL

EVS300W/600W

Series

TDK­Lambda

<Page>

BEFORE USING THE PRODUCT

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before 
using this product. Incorrect usage could lead to an electrical shock, damage to the product or a fire hazard.

DANGER

Never use this product in locations where flammable gas or ignitable substances are present.

INSTALLATION WARNING

When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is 
risk of electric shock and fire.

Installation shall be done by Service personnel with necessary and appropriate technical training and experience. There is a 
risk of electric shock and fire.

Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage, 
electric shock or fire.

WARNING on USE

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a 
burn.

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation.

For products with no cover, do not touch them as there are high­voltage and high temperature parts inside. Touching them 
might cause injury such as electric shock or burn.

There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in 
operation as you might get injured due to high voltage and high temperature. You might also get electric shock or burn.

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage 
the product. We will not be held responsible after the product has been modified, changed or dis­assembled.

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop 
using it immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. Do 
not attempt repair by yourself, as it is dangerous for the user.

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might 
lead fire and electric shock.

Do not drop or apply shock to this product. It might cause  failure. Do not operate these products mechanical stress is 
applied.

CAUTION on MOUNTING

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on.

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within 
specifications, otherwise the product will be damaged.

Input line, please use the wires as short and thick as possible.

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and 
direct sunlight, or places where product is exposed to water  or rain.

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be 
ventilated.

Please shut down the input when connecting input and output of the product.

When mounted in environments where there is conductive foreign matter, dust of liquid, there is possibility of product
failure or malfunction. Such as install filter, please consider that a conductive foreign matter, dust and liquid do not invade
inside the product.

CAUTION on USE

Product individual notes are shown in the instruction manual. If there is any difference with common notes individual notes 
shall have priority.

Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the
product or fire due to improper use.

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within
specifications, otherwise the product will be damaged, or cause electric shock or fire.

1/22

A269­04­01B

EVS300W/600W Series

Instruction Manual

Содержание EVS300W Series

Страница 1: ...and sound etc Please stop using it immediately and shut off the product It might lead to fire and electric shock In such cases please contact us Do not attempt repair by yourself as it is dangerous f...

Страница 2: ...field corrosive gas or conductive substances and direct sunlight or places where product is exposed to water or rain The product on this instruction manual are PC Board Type 300W and Unit Type 600W w...

Страница 3: ...terminal of TB1 Output terminal M4 screw Output terminal M4 screw V ADJ Output voltage adjustment trimmer The output voltage rises when a trimmer is turned clockwise Remote ON OFF control terminal Opt...

Страница 4: ...nt Adjustment Method for usage EVS600W Option R Remote ON OFF control terminal Option R Hand Crimping Tool YRS 620 SPHD 002T P0 5 JST or YC 610R SPHD 001T P0 5 JST Use maker recommended crimping tool...

Страница 5: ...300W EVS300W Option R RA EVS600W EVS600W Option R Recommended torque M3 5 screw 1 0N m 10 2kgf cm 1 6N m 16 3kgf cm M4 screw 1 2N m 12 3kgf cm 1 6N m 16 3kgf cm M5 screw 2 2N m 22 4kgf cm 2 8N m 28 6k...

Страница 6: ...he inrush current value specified in the specification is under cold start condition at 25o C Inrush current is suppressed by thyristor for EVS600W Higher current may flow when input turn on interval...

Страница 7: ...has experiences in adjustment works Method of Constant Current Setting 1 Power off the product and set constant current to required value by output constant current adjustment rotary switch Refer to E...

Страница 8: ...ct your nearest TDK Lambda sales office with the details of usages and conditions 8 22 No 0 No 1 No 2 No 3 No 4 No 5 No 6 No 7 No 8 No 9 9 0 10 1 11 2 12 4 13 5 14 7 15 6 16 7 9 3 10 4 11 5 12 7 13 8...

Страница 9: ...justment trimmer I ADJ counterclockwise until output voltage starts to fall Refer to EVS600W Output Constant Current Set Point on positions of output constant current adjust trimmer Refer to EVS600W O...

Страница 10: ...e between output and must be less than withstand voltage 500VAC In addition take note that using the product with total output voltage 60V or more does not comply with SELV in safety standard In serie...

Страница 11: ...o same voltage The difference of each product output voltage should be within 5 2 Adjust the output voltage higher by the value of the voltage drop 90mV typ of EVS RP or the forward voltage drop Vf of...

Страница 12: ...thstand voltage tester may generate high voltage due to distortion of test voltage and may cause the product damage So please check the waveform of applied voltage Note 2 In case of using external noi...

Страница 13: ...ount the product in any other directions EVS600W Possible mounting directions are A B C and D only Do not mount the product in any other directions Do not exceed the derating of maximum load which is...

Страница 14: ...0 10 20 30 40 50 60 70 80 Load Ta 0 20 40 60 80 100 120 20 10 0 10 20 30 40 50 60 70 80 Load Ta Ta C 20 10 20 30 40 50 60 Load Mounting D E 100 84 68 52 36 20 Mounting A B Mounting C Mounting D Mount...

Страница 15: ...reference set wind velocity at 1 4m s 15 22 Mounting A E Ta C 20 50 60 C6 C52 75 75 Load Mounting A E 100 70 Cooling Wind velocity 1 4m s Electrolytic capacitor allowable Max temperature Allowable Max...

Страница 16: ...f maximum output current value in a rated output voltage EVS300W EVS600W 16 22 Mounting A D Ta C 20 50 60 70 20 Load Mounting A D 100 60 Load 80 85 100 90 265 Input Voltage VAC Input Voltage VAC 80 85...

Страница 17: ...pieces is 9mm from each PCB corners Refer to figure below If the space is not enough the specification of isolation and withstand will not be satisfied Take the space in the product surroundings and...

Страница 18: ...ype product This product has ventilating holes Keep a space more than 50mm between front side of the product and peripheral parts Back side as well Also keep a space more than 5mm between other surfac...

Страница 19: ...ary depending on actual conditions Choose most appropriate wire type and crimp type terminal by refer to wire maker recommended allowable current and voltage drop 6 Radiated Emission EVS600W only It i...

Страница 20: ...life expectancy of the product is calculated in condition of rated input voltage and 24 hour continuous operation Load is percent of maximum output current in a rated output voltage EVS300W EVS300W A...

Страница 21: ...VS600W 15A 9 Before concluding that the product is at fault Before concluding that the product is at fault make the following checks 1 Check if the rated input voltage is connected 2 Check if the wiri...

Страница 22: ...is free of charge Please contact our sales office for warranty in other mounting directions if required EVS300W 1 Convection Cooling 2 Forced Air Cooling Mounting A Mounting A E EVS600W Mounting A Fol...

Отзывы: