14. I

SOLATION AND 

D

IELECTRIC 

S

TRENGTH

 

The output voltage is floating and has no ohmic 

connection to the input or PE. 

B

C

N

L

Input

Earth, PE

Output

 -

+

A

A

N

L

Input

Output

 -

+

DTM160:

DTM160-C8:

Hi-pot tests may be repeated by the customer using 
appropriate test equipment, which applies the voltage 

with a slow ramp (2s up and 2s down). Connect all 

input-terminals together as well as all output poles 
before conducting the test. 
 
 

 

 

DTM160 DTM160-C8 

 

Dielectric strength 

Min. 

4400Vac 

4400Vac 

Input to output (A) for 1 minute 

 

Min. 

1800Vac 

Input to PE (B) for 1 minute 

 

Min. 

1800Vac 

Output to PE (C) for 1 minute 

Isolation resistance 

Min. 

100M

Ω

 100M

Ω

 

Input to output (A) 

 

15. S

AFETY AND 

P

ROTECTION 

F

EATURES

 

Under voltage protection (UVP) 
Shut-down voltage 

Min. 
Typ.

Max. 

60Vac 
65Vac 

70Vac 

For all models 

Output over voltage protection (OVP) 

Typ.
Typ.
Typ.

Typ. 

13.2V 
28.6V 
41.8V 

55.6V 

For DTM160CN120, DTM160CN120C8 
For DTM160CN240, DTM160CN240C8 
For DTM160CN360, DTM160CN360C8 
For DTM160CN480, DTM160CN480C8 
In case of an internal defect, a redundant circuit 
limits the maximum output voltage. The output 
shuts off. Cycle input voltage to restart. 

Output over-current protection (OCP) 

Min. 
Max. 

110%  
130% 

Of the nominal output current, auto recovery 

Output short-circuit protection (SCP) 

 

Included 

Continuous, automatic recovery  

Class of protection 

 


II 

For all DTM160 
For all DTM160-C8 

According to IEC 61140 

Degree of protection 

 

IP 22 

According to EN/IEC 60529 

Input transient protection 

 

MOV 

For protection values see EMC chapter. 

Internal input fuse 

 

Included 

Not user replaceable slow-blow high-braking 

capacity fuse 

Earth leakage current 

Max. 

300µA 

For DTM160 

Touch current 

Max. 

90µA 

For DTM160 and DTM160-C8 

 

All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless  
otherwise noted. The information presented in this document is believed to be accurate and reliable and may change without notice. 

For additional information, please visit 

https://product.tdk.com/en/power/dtm

 

11/13

DOC-ID: 260933 – Issue 1

Содержание DTM160 Series

Страница 1: ...y Curves 7 11 EMC 8 12 Physical Dimensions Weight and Connectors 9 13 Environment 10 14 Isolation and Dielectric Strength 11 15 Safety and Protection Features 11 16 Approvals and Regulatory Compliance...

Страница 2: ...the compact design achieved by the high efficiency and the standard locking DIN output connector which prevents unintentional output voltage disconnection Other connector versions and cable assemblies...

Страница 3: ...The device is designed to operate in areas with a maximum relative humidity of 93 4 INSTALLATION INSTRUCTIONS Before operating this device please read this manual thoroughly and retain this manual for...

Страница 4: ...itive load is higher than the values specified the device operates in an intermittent mode hiccup mode See short form data table for maximum values The output voltage is fixed and can not be adjusted...

Страница 5: ...xternal Adapter Power Supply Class I 160W 48V 3 33A DTM160CN120C8 External Adapter Power Supply Class II 150W 12V 12 5A DTM160CN240C8 External Adapter Power Supply Class II 160W 24V 6 66A DTM160CN360C...

Страница 6: ...0CN120 DTM160CN120C8 For all remaining models Bandwidth 20MHz 25degC ambient 100nF ceramic capacitors and 10uF aluminium capacitor to output Efficiency Typ Typ Typ Typ 91 0 92 0 92 0 93 0 For DTM160CN...

Страница 7: ...ency vs output load DTM160CN360 DTM160CN360C8 Efficiency vs output load DTM160CN480 DTM160CN480C8 Efficiency vs output load All parameters are typical values specified at nominal input voltage nominal...

Страница 8: ...les class 3 80Vac 250 300 cycles class 3 Criterion A Criterion A Criterion B Criterion A Criterion A Voltage interruptions EN 61000 4 11 EN 60601 1 2 AC 100 120 230Vac 0Vac 250 300 cycles class 3 Crit...

Страница 9: ...KPPx 4P or equivalent P1 P2 Vout P3 P4 Vout Alternative output connectors are available Please contact Sales for further information minimum quantities apply All parameters are typical values specifie...

Страница 10: ...rding to IEC 60664 1 Degree of pollution 2 According to IEC 62477 1 not conductive Vibration sinusoidal 4g 15 2000Hz 60 minutes per axis According MIL STD 810F Table 514 5C VIII sinusoidal vibration u...

Страница 11: ...0 DTM160CN240C8 For DTM160CN360 DTM160CN360C8 For DTM160CN480 DTM160CN480C8 In case of an internal defect a redundant circuit limits the maximum output voltage The output shuts off Cycle input voltage...

Страница 12: ...t 1 General requirements for basic safety and essential performance Part 1 6 Collateral standard Usability Part 1 11 Collateral Standard Requirements for medical electrical equipment and medical elect...

Страница 13: ...oted The information presented in this document is believed to be accurate and reliable and may change without notice For additional information please visit https product tdk com en power dtm 17 PACK...

Отзывы: