BEFORE USING THE POWER SUPPLY UNIT   

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using 
this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

 

 

DANGER 

Never use this product in locations where flammable gas or ignitable substances are present.

 

 

INSTALLATION WARNING

 

 

When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is risk of 
electric shock and fire.   

 

Installation shall be done by Service personnel with necessary and appropriate technical training and experience. There is a risk of 
electric shock and fire.   

 

Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage, electric shock 
or fire. 

 

WARNING ON USE

 

 

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a burn. 

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation.   

 

For products with no cover, do not touch them as there are high-voltage and high temperature parts inside. Touching them might 
cause injury such as electric shock or burn. 

 

There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in operation as 
you might get injured due to high voltage and high temperature. You might also get electric shock or burn.   

 

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage the 
product. We will not be held responsible after the product has been modified, changed or disassembled.   

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop using it 
immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. Do not attempt repair 
by yourself, as it is dangerous for the user. 

 

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might lead fire 
and electric shock. 

 

Do not drop or apply shock to this product. It might cause failure. Do not operate these products, when mechanical stress is applied. 

 

CAUTION ON MOUNTING

 

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. 

 

Input 

/

Output line, please use the wires as short and thick as possible. 

 

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and direct 
sunlight, or places where product is exposed to water or rain. 

 

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be ventilated. 

 

Please shut down the input when connecting input and output of the product. 

 

When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration of above 
foreign material in the power supply by installing filter, to prevent trouble or malfunction. 

 

 

 

 

 

 

 

Содержание CUS800M

Страница 1: ...e to high voltage and high temperature You might also get electric shock or burn Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damag...

Страница 2: ...re there is conductive foreign matter or dust there is possibility of product failure or malfunction Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to...

Страница 3: ...uts have basic spacing s to earth rated for mains 250Vac and due consideration must be given to this in the end product design Important safety instructions Servicing These products are not customer s...

Страница 4: ...ange 5 C 30 C Humidity range 40 60 RH Please keep away from the places where temperature and humidity can change drastically It can cause condensation on the product or deterioration For long term sto...

Страница 5: ...lank Standard type SF Single fuse model 2 Terminal Explanation Input side Top side L Input terminal Live line Fuse in line M3 screw N Input terminal Neutral line Fuse in line M3 screw Functional earth...

Страница 6: ...e ON OFF terminal Please refer to 6 14 8 R Remote ON OFF terminal Please refer to 6 14 TB1 CN51 CN61 Connector Housing Terminal Pin Connectors used Matching housings Matching pins Maker Input TB1 T825...

Страница 7: ...ain Output ON OFF Control V DC_OK detection S S R R Fuse rating 16A Circuit topology switch frequency PFHC circuit active filter 65kHz Typ Output circuit LLC resonant 50k 300kHz Standby supply circuit...

Страница 8: ...me chart 2 Input voltage Standby Supply Remote ON OFF 2 Main Output PG signal OCP act on 0V 0V R 0V 0V Remote ON Remote OFF 100ms OCP reset DC_OK monitor point R Remote ON OFF 2 Standby Supply off OCP...

Страница 9: ...nts when connecting or removing connectors Remote ON OFF control lines shall be twisted or used shielded wires Separate from load line Remote sensing lines shall be twisted or used shielded wires End...

Страница 10: ...OFF and then remote ON again Refer to 6 14 6 5 Over Temperature Protection OTP Over temperature shut down function is provided When ambient or internal temperature rises abnormally over temperature p...

Страница 11: ...ossible Power Supply Power Supply 4 Please select a reverse current prevention diode with maximum forward current rating more than output load current V V V V 4 6 10 Isolation Test Isolation resistanc...

Страница 12: ...sofoutputvoltage since ACfailthrough PGand STBY Power Good signal shows High level 4 5V 5V to indicatepowersupply operating normal and can sourcemaximum2mAcurrent When powersupply stopsoperating thesi...

Страница 13: ...inals to load terminals Connect S terminal to terminal of load and S terminal to terminal of load with sensing wires The total line voltage drop side line and side line shall be less than 0 5V In case...

Страница 14: ...should be considered Please refer to the output derating versus input voltage curve 6 1 for detail Main Output Derating versus Operating Ambient Temperature Ta Main Output Power Derating versus High O...

Страница 15: ...to 4 secondsis allowed T1 4 s 3 Maximumduty ofpeak powershould belessthan 40 1 1 2 40 7 3 Mounting Method 1 These models are forced air cooling type power supply The power supply has ventilating hole...

Страница 16: ...dered by in rush current value at line turn on Do not select the fuse according to input current RMS values under the actual load condition CUS800M series F16AH 11 Before concluding that the unit is a...

Страница 17: ...ance with the Low Voltage Directive EMC Directive and RoHS Directive UKCA MARKING UKCA Marking when applied to a product or packing material for a product covered by this handbook indicates compliance...

Отзывы: