BEFORE USING THE POWER SUPPLY UNIT

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before 
using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

DANGER

  Never use this product in locations where flammable gas or ignitable substances are present.

INSTALLATION WARNING

  When installing this product, ensure that work is done in accordance with the instruction manual. When installation is 

improper, there is risk of electric shock and fire. 

  Installation shall be done by service personnel with necessary and appropriate technical training and experience. There is a 

risk of electric shock and fire. 

  Do not cover the product with cloth, paper and etc. Do not place any flammable object around the product. This might cause 

damage, electric shock or fire.

WARNING ON USE

  Do not touch this product or its internal components while product is in operation, or shortly after shutdown. You may 

    receive a burn.

  While this product is operating, keep your hands and face away from it as you might get injure from an unexpected 

situation. 

  For product without cover, do not touch this product or its internal components while product is in operation, or shortly 

after shutdown. There are high voltage potential and high temperature parts in the product. This might cause injury such as 
electric shock or burn.

  There are cases where high voltage charge remains inside the product immediately after the input is cut off. Do not touch 

even if product is not in operation as you may get injure from electrical shock and burn. 

  Do not make unauthorized change to this product or remove the cover as you may get injure from electric shock or damage 

the product. We will not be held responsible if the product was modified, changed or disassembled. 

  Do not use this product under unusual conditions such as emission of smoke or abnormal smell and sound etc. Please stop 

    using it immediately and shut off the product. It might lead to fire and electric shock. 

In such cases, please contact to TDK-lambda. Do not attempt any repair by yourself, as this may cause injuries to yourself.

  Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might 

lead fire and electric shock.

  Do not use the product when there is mechanical over-stress or heavy impact to the product as it might cause failure.

  When necessary, this product is to be repaired by TDK-Lambda or our authorized agents. It is important that this product 

must not be used in hazardous environments or facilities such as nuclear power control system or life support equipment 
without our written consent.

CAUTION ON MOUNTING

  Ensure connections to input/output terminals are correct as indicated in the instruction manual before switching on.

  Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within 

specifications, otherwise the product will be damaged. 

  Input wires must be as short and thick as possible.

  Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances 

    and direct sunlight, or places where product is exposed to water or rain.

  Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly ventilated.

  Please shut down the input when connecting input and output of the product.

  When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration of 

these foreign material in the power supply by installing filter, to prevent trouble or malfunction.

  Please install power supply in a fire enclosure.

1/20

PA644-04-01

CUS350MP-1000 Series

Instruction Manual

Содержание CUS350MP-1000 Series

Страница 1: ...will not be held responsible if the product was modified changed or disassembled Do not use this product under unusual conditions such as emission of smoke or abnormal smell and sound etc Please stop...

Страница 2: ...nnected together there is risk of electric shock Parts with lifetime specifications electrolytic capacitor is required to be replaced periodically Set the overhaul period depending on the environment...

Страница 3: ...HOD AND DURATION PERIOD Always keep the product in carton box Please do not apply excessive vibration shock or mechanical stress directly to the product Please keep away from direct sunlight For long...

Страница 4: ...Earth Terminal Mounting hole hole diameter 3 5mm These holes are connected to terminal of CN1 Must be connected to Chassis Conductor of the equipment by screw or metal spacer Output Terminal Output Te...

Страница 5: ...ON OFF control terminal 2 RO Remote ON OFF control terminal External switch is required and switch open to turn on power supply Do not connect to pin 6 and 8 and do not connect external voltage If it...

Страница 6: ...ive filter 100kHz fixed Standby supply flyback converter 100kHz jittering Fuse rating 16A 6 20 Line Filter Rectifier Inrush Current Limit Circuit Filter L N Primary Current Sensing Photo coupler Input...

Страница 7: ...voltage 1 OVP detection point is fixed Refer to specification 2 External switch is required Refer to section 6 13 Remote ON OFF control 3 Peak loading duration more than specified timing is caused out...

Страница 8: ...sitivity When connecting or removing connector do not apply stress to PCB Use input output connector housing specified by the table below Connector is not included with this product Use recommended cr...

Страница 9: ...on the output current When the delay shutdown is triggered the output will shutdown and manual reset of power supply or remote control off on is required to re power on Use this power supply within p...

Страница 10: ...he bypass diode must be selected with maximum forward current rating and maximum reverse voltage rating of more than output current and output voltage 6 10 Parallel Operation Method A that to increase...

Страница 11: ...et current limit of the withstand voltage test equipment to 10mA output terminal 20mA The withstand voltage must be gradually increased from zero to the testing value and then gradually decreased for...

Страница 12: ...rt piece connector at shipment The short piece must be removed to perform remote ON OFF control function Remote ON OFF circuit is in the secondary side of the power supply and it is isolated from outp...

Страница 13: ...3 Output Derating according to the Mounting Direction This series can be used under convection cooling and forced air cooling In the case of using at forced air cooling components must be cool down A...

Страница 14: ...h of peak current must be less than or equal to 1 sec When input voltage is less than 170VAC output derating is required Refer to d Output Derating according to the Input Voltage for details The produ...

Страница 15: ...5 265 MAXIMUM OUTPUT POWER W INPUT VOLTAGE VAC Wp 800W Convection cooling Wp 800W Forced air cooling 0 100 200 300 400 500 600 85 105 125 145 165 185 205 225 245 265 MAXIMUM OUTPUT POWER W INPUT VOLTA...

Страница 16: ...II FORCED AIR COOLING 16 20 0 20 40 60 80 100 20 10 0 10 20 30 40 50 60 70 80 LOAD OPERATING AMBIENT TEMPERATURE C MOUNTING A MOUNTING B C F MOUNTING D E 0 20 40 60 80 100 20 10 0 10 20 30 40 50 60 7...

Страница 17: ...BLE COMPONENT TEMPERATURE Electrolytic capacitor Equipment must be re evaluated for electrolytic capacitor lifetime 17 20 Measurement point Symbol Item description Allowable temperature C A CN1 Input...

Страница 18: ...o the Mounting Direction 7 5 Mounting Method Mount the power supply by M3 screw or metal spacer and use all mounting holes for installation There are cases where the baseplate will be high temperature...

Страница 19: ...surrounding of power supply for convection cooling terminal terminal should be connected to the protective earth terminal of the equipment Also 4 mounting holes should be connected to the Chassis Con...

Страница 20: ...fer to the following fuse rating when selecting the external fuse that is to be used on input line Surge current flows when line turns on Slow blow or time lag type fuse is required to use Fast blow f...