INSTRUCTION MANUAL

CUS200LD

TDK-Lambda

<Page>

4-6.

Output Ripple & Noise

The measurement circuit of the output ripple and noise in the specifications is shown below. If the load wires are
longer, the ripple and noise will be higher. In this case, electrolytic capacitor, film capacitor, etc. might be
necessary to be used across the load terminal. The ground lead of probe should be short to avoid the noise
interference

4-7.

Series Operation

For series operation, either method (A) or (B) is possible.

Method (A)

Method (B)

Note :
In case of method (A), it is recommended to connect the bypass diodes, power supply might be damaged
without bypass diodes.
Please select a bypass diode with maximum forward current rating more than output load current. And
maximum reveres voltage must withstand output voltage of each power supply.
Series operation is possible without bypass diode, but make sure all units must be in operation.
(Never use in condition that one of the units is not operated.)

4-8.

Parallel Operation

For parallel operation, method (B) is possible.

(A) To increase the Output Current is not possible.

(B) Operation as a Backup System is possible.

1. Adjust the output voltage higher to compensate

the forward voltage drop (VF) of the diode.

2. Adjust each power supply output to same voltage.
3. Output voltage and output power should be used

within specifications.

4. Use blocking diode to prevent reverse current.

Diode current rating must be more than output load
current.

Power

Supply

Power

Supply

Load

+V

-V

+V

-V

+

-

Power

Supply

Power

Supply

Load

+V

-V

+V

-V

+

-

-V

-V

+V

+V

+

-

Load

Power

Supply

Power

Supply

Bypass diodes

-V

-V

+V

+V

+

+

-

-

Load

Load

Power

Supply

Power

Supply

4/9

Load

C1

150mm

C2

Coaxial Cable

1.5m 50

R1

C3

Bandwidth : 20MHz 

Power

Supply

+

-

C1 : 0.1uF   Cap., Film
C2 : 100uF  Cap., Elect
C3 : 4700pF Cap., Ceramic
R1 : 50

Oscilloscope

Содержание CUS200LD

Страница 1: ...ce Environmental These products are IPX0 and therefore chemicals solvents cleaning agents and other liquids must not be used Environment This power supply is a switch mode power supply for use in appl...

Страница 2: ...mechanical electric shock and fire hazard protection Energy Hazards The main output of this product is capable of providing hazardous energy 240VA Final equipment manufacturers must provide protectio...

Страница 3: ...in der finalen Gesamtinstallation betrachtet werden Bitte kontaktieren Sie Ihr regionales TDK Lambda Vertriebsb ro im Falle von R ckfragen Umwelt Diese Produkte sind IPX0 aus diesem Grund d rfen kein...

Страница 4: ...Stromschl gen und Brandschutz in dem Endger t vorgesehen werden Gefahren durch elektrische Energie Von bestimmten Modulen kann je nach Einstellung der Ausgangsspannung gef hrliche elektrische Energie...

Страница 5: ...r votre bureau TDK Lambda le plus proche Environnement Ces produits sont IPX0 et donc on ne doit pas utiliser des produits chimiques solvants des produits de nettoyage et d autres liquides Environneme...

Страница 6: ...assurer la protection contre les chocs m caniques les chocs lectriques et l incendie Energies dangereuses Certains modules peuvent g n rer une nergie dangereuse 240 VA selon le r glage de tension de...

Страница 7: ...no a vostra disposizione per ulteriori ragguagli Condizioni ambientali Questi prodotti sono classificati come IPX0 dunque non devono essere utilizzati sostanze chimiche solventi prodotti per la pulizi...

Страница 8: ...ettriche e dai pericoli di incendio Pericoli energetici Alcuni moduli sono in grado di erogare energia pericolosa 240 VA a seconda della tensione in uscita impostata I produttori delle apparecchiature...

Страница 9: ...to con su oficina local de TDK Lambda Medioambiental Estos productos son IPX0 y por tanto no pueden utilizarse sustancias qu micas disolventes agentes de limpieza ni otros l quidos Medio ambiente Esta...

Страница 10: ...endios de protecci n mec nica contra descargas el ctricas y contra el peligro de incendios Peligros de energ a Algunos m dulos pueden generar energ a peligrosa 240VA dependiendo de la configuraci n de...

Страница 11: ...contacto com seu escrit rio TDK Lambda mais pr ximo Ambiental Estes produtos s o IPX0 e como tal n o se devem utilizar qu micos solventes agentes de limpeza e outros l quidos Ambiente Esta fonte de a...

Страница 12: ...gosa 240 VA de acordo com a configura o da tens o de sa da O equipamento final do fabricante deve garantir que o pessoal de assist ncia est protegido contra contactos inadvertidos com estes terminais...

Страница 13: ...tput current Output power ambient temperature and ambient humidity should be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment wh...

Страница 14: ...nt trimmer Output monitoring indicator Green LED Mounting hole hole diameter 3 8mm All screws size is M3 0 3 Connecting method Pay attention to the input wiring If it is connected to wrong terminal th...

Страница 15: ...ure or input re power on Please select input switch or external fuse carefully The inrush current value specified in the specification is under cold start condition at 25 4 4 Over Voltage Protection O...

Страница 16: ...each power supply Series operation is possible without bypass diode but make sure all units must be in operation Never use in condition that one of the units is not operated 4 8 Parallel Operation For...

Страница 17: ...INSTRUCTION MANUAL CUS200LD TDK Lambda 4 9 Isolation Test 4 10 Withstand Voltage Instructions for using the power supply in customer s system 4 11 Surge Immunity Test IEC61000 4 5...

Страница 18: ...ting curve of maximum output power and output current Please refer to Input Voltage Derating 4 1 and Output Derating 5 3 for details 5 Mounting 5 1 Mounting Method 1 For both conduction and convection...

Страница 19: ...the effectiveness of the heat sink and both Ta and Tb must not exceed the derating curve below for safety operation of the power supply Maximum output power and output current derating vs ambient tem...

Страница 20: ...lation wiring grounding and end application of the switching power supply in the equipment system may influence its EMC characteristics Therefore the EMC performance has to be tested on end system lev...

Страница 21: ...iring of input and output is correct 3 Check if the wire size is not too thin 4 Check if the output voltage is properly adjusted 5 Check if the output current and output power does not over specificat...

Отзывы: