TDK-Lambda 

CN-A110 Series 
Instruction Manual

 

 

 

CN-A110 SERIES

 

 

 

Instruction Manual 

 

BEFORE USING THE POWER SUPPLY UNIT 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect 
usage could lead to an electrical shock, damage to the unit or a fire hazard. 

 

DANGER

 

·

 

Never use this product in locations where flammable gas or ignitable substances are present. 

 

WARNING

 

·

 

Do not touch this product or its internal components while it is in operation, or within 5 seconds of shut down. There may be high voltage or high temperature 

present and you may receive an electric shock or burn. 

 

·

 

When the product is operating, keep your hands and face away from it as you may be injured by flying debris in the event of a fault. 

·

 

Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty. 

·

 

Do not use this product in the event of the emission of smoke or abnormal smell and sound etc. It might lead to fire and/or electric shock. In such cases, please 

contact us. Do not attempt repair by yourself, as it is dangerous for the user. 

·

 

Do not operate these products in the presence of condensation. It might lead to fire and/or electric shock. 

 

 

·

 

Do not drop or insert anything into the product. It might lead to a failure, fire and/or electric shock.

 

 

CAUTION

 

 

·

 

This power supply is designed for use within an end product such that it is accessible to SERVICE ENGINEERS only. 

·

 

Confirm connections to input/output terminals and signal terminals are correct as indicated in the instruction manual before switching on. 

·

 

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, otherwise the product will be 

damaged. 

·

 

Do not operate and store this product in an environment where condensation might occur. In such case, waterproof treatment is necessary. 

·

 

Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances.

 

 

·

 

For  applications  which  require  very  high  reliability  (Nuclear  related  equipment,  traffic  control  equipment,  etc.),  it  is  necessary  to  provide  a  fail  safe 

mechanism in the end equipment. 

·

 

The information in this document is subject to change without prior notice. Please refer to the latest version of the data sheet, etc., for the most up-to date 

specifications of the product. 

·

 

No part of this document may be copied or reproduced in any form without prior written consent of TDK-Lambda. 

·

 

Do not inject abnormal voltages into the output or signal of this product. The injection of reverse voltage or over voltage exceeding nominal output voltage 

into the output or signal terminals might cause damage to internal components. 

·

 

Operation  of  this  product  under  over-current  or  short  circuit  conditions  can  result  in  damage.  Failures  of  the  product  under  these  conditions  have  been 

assessed and are considered to be safe within the meaning of IEC/EN/UL/CSA 60950-1. 

·

 

This product contains  a  printed  circuit  board  utilizing  surface  mounted  devices.  PCB  stress  such  as  bending,  twisting  etc  could  cause  damage.  Therefore, 

please handle with care. 

·

 

In order to maintain SELV output, the baseplate must be protectively earthed in the end application. Where the baseplate is not earthed, the output must be 

considered hazardous and must not be made user accessible" 

·

 

The output of this product may, under fault conditions, exceed SELV voltage limits. Therefore the output must be earthed in the end equipment to maintain 

SELV. If the output is not earthed, they must be considered hazardous and must not be made user accessible. 

·

 

These products have been assessed for use with non-isolated mains derived DC where the mains source is up to 115VAC. For mains derived DC above this 

source voltage, there must be isolation equivalent to reinforced insulation at the rated mains source voltage. 

·

 

The application circuits and their parameters are for reference only. Be sure to verify effectiveness of these circuits and their parameters before finalizing the 

circuit design. 

·

 

Use an HBC external fuse to each module to ensure safe operation and compliance with the Safety Standards to which it is approved.

 

 

  Note : CE MARKING 

CE Marking, when applied to a product covered by this handbook, indicates compliance with the low voltage directive. 

 

 
 
 
 
 
 

 

Содержание CN-A110 Series

Страница 1: ...require very high reliability Nuclear related equipment traffic control equipment etc it is necessary to provide a fail safe mechanism in the end equipment The information in this document is subject...

Страница 2: ...OCP 8 Over Voltage Protection OVP 9 Over Temperature Protection OTP 10 Remote Sensing S S terminal 11 ON OFF Control CNT terminal 12 Parallel Operation PC terminal 13 Series Operation 14 Operating Amb...

Страница 3: ...m Sequence Time Chart Vin Vin CNT V V TRM S S Switching frequency fixed 400kHz PC Only CN200A110 12 15 24 ON OFF Only 5V Model Only 5V Model 300kHz Only CN200A110 5 400kHz 300kHz CN200A110 5 Model onl...

Страница 4: ...Terminals Output Side Terminals Vin Input Terminal V Output Terminal PC NC Output Current Balance Terminal S Remote Sensing Terminal PC Terminal 12 15 24V Models TRM Output Voltage Trimming Terminal N...

Страница 5: ...A110 DC400V and above 4A CN200A110 DC400V and above 10A C1 To prevent the effect of input line inductance to the power module connect electrolytic capacitor between Vin and Vin terminals Furthermore u...

Страница 6: ...on Chemi con LXZ LXY Series or equivalent 2 Use more than two recommended capacitor above in parallel when ambient temperature becomes lower than 20 to reduce ESR 3 Take note of the allowable ripple c...

Страница 7: ...output voltage higher 2 1 Allowable maximum output current maximum output power output voltage reduce maximum output current specification 2 2 Connect an external resistor Radj up between TRM termina...

Страница 8: ...cable with JEITA attachment Use oscilloscope with 100MHz frequency bandwidth or equivalent Fig 3 1 Measurement of Maximum Output Ripple and Noise Take note that output ripple voltage and output spike...

Страница 9: ...ion This function operates and shuts down the output when ambient temperature or internal temperature of power module abnormally rises OTP operates at 105 to 120 baseplate temperature OTP can be relea...

Страница 10: ...ule malfunction Notes 1 Output voltage accuracy of each module should be set within 1 when using in parallel operation 2 Maximum output current of each module should be derated at 90 or less 3 Use the...

Страница 11: ...re is 100 For worst case operating condition verify baseplate temperature at measurement point indicated in fig 14 1 a CN30 50 100A b CN200A Fig 14 1 Measurement Point of Baseplate Temperature Fig 14...

Страница 12: ...kVAC 1 minute Fig 19 2 Withstand Voltage Test for Input Baseplate 500VAC 1 minute Fig 19 3 Withstand Voltage Test for Output Baseplate Fig 19 1 to Fig 19 3 PC NC terminal available only for CN200A Mod...

Страница 13: ...hen the applied voltage is varied Ensure that the tester is fully discharged after the test Over 100M at 500VDC Fig 20 1 Isolation Test Fig 20 1 PC NC terminal available only for CN200A Model 21 Vibra...

Страница 14: ...iameter 2 5 mm Land diameter 5 0 mm Mounting Holes FG Hole diameter 3 5 mm Land diameter 7 0 mm For position of the holes see outline drawing of the power module 4 Recommended Material of PCB Recommen...

Страница 15: ...ibration The vibration specification of the module is determined assuming that only the power module is mounted on printed circuit board To prevent excessive force to the module and the printed circui...

Страница 16: ...ng points For cases where output voltage adjustment is used is the resistor or volume setting connections correctly done 3 Output voltage is low Is specified input voltage applied Are the remote sensi...

Отзывы: