3. Description

The measurement types volt AC/DC, ampere AC/DC, frequency and 5 A or 1 A for 
current   transformer   are   supported.   The   unit   can   be   switched   between  different 
measurement modes via an external switch. Minimum and maximum values are re-
corded and can be displayed optionally using an external switch. Measured values 
are recorded over a time span of 36 seconds up to 14 days. The time base as well 
as the display of the measuring history can be switched by an external switch. The 
measured values remain stored as long as the device is supplied with voltage.

2

4

3

1

Front

1

Measurement unit

2

Upper scale caption

3

Graphical measurement display

4

Digital measurement value

Supply

12 - 24 V

~/

 

   

+

Digalox DPM72-PP

www.digalox.com
Made in Germany

      100 mA max.       Shunt 333 mV max.

I

low

I

high

U

high

U

low

Outputs max.

30 V

50 mA

Supply

12 - 24 V

~/

 

   

+

Digalox DPM72-AV

www.digalox.com
Made in Germany

2

1

4

3

Back

1

DIP   switch   for   setting   upper 
scale caption and measurement 
mode

2

Supply voltage input

3

Jumper pins J1 – J6 for activat-
ing/switching of graphical historic 
data   display,   min/max   display, 
auto-scaling   and   measurement 
mode

4

Measurement inputs

----- 

2

 -----

Содержание Digalox DPM72-AV

Страница 1: ...ement inputs of the device can carry life threaten ing voltages WARNING When working on the device hazardous voltages must not be connected to the device The terminals J1 J6 are not isolated from the...

Страница 2: ...ernal switch The measured values remain stored as long as the device is supplied with voltage 2 4 3 1 Front 1 Measurement unit 2 Upper scale caption 3 Graphical measurement display 4 Digital measureme...

Страница 3: ...rrent via current transformer and voltage direct Digalox Load Current transformer Ilow Ihigh Uhigh Ulow max 10 A FF L N max 500 V Current via current transformer on high side and voltage direct Digalo...

Страница 4: ...easurement modes via an external switch Save mode The required measurement modes are configured and saved sequentially 1 Set DIP switch 10 11 and 12 to OFF position 2 Connect supply voltage 3 Set the...

Страница 5: ...iguration proceed as follows 1 Connect supply voltage 2 Set DIP switches 1 9 to OFF position 3 Set DIP switch 10 to ON position 4 Start with 1st switch 5 Set switch to ON position 6 If the displayed v...

Страница 6: ...4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 A AC direct Ampere AC ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 J1 J6 V DC direct Volt DC ON 1 2 3 4...

Страница 7: ...e setting permanently DIP switch 10 must be switched from ON to OFF position J2 Min Max display The display shows the maximum and min imum values recorded since the last reset The values can be reset...

Страница 8: ...requency 10 1000 Hz Accuracy frequency 0 1 Hz Measuring value update 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 internal memory locations Operating temperature 0 C to...

Отзывы: