JM50 Rapid Roller Door Operator 

 
 

 

 
 

Fig.3 

 

 

Make sure the door shaft which out of the door operator about 160mm. 

 

To install the bracket on the fix board, determine the location, mark and drill the  2 holes 
(

Ø

11).   

 

Fix the bracket on the operator with 4 screws M8x16. Make sure that the bracket is plumb 

and lever. See Fig.2 

 

The bracket installation should meet the specifications as shown in figure 3 

 

Slot the door operator with bracket onto the door shaft (ensure correct position of the key) 

and screw onto the fix board with 2 bolts M10×25 and 2 nuts M10.

 

 

Slot the encoder onto the door shaft and push it close to the door operator and screw onto 

the door operator with screw M8×16. 

 

Tight  the  screw  on  the  encoder,  make  sure  the  encoder  rotates  with  the  shaft 

simultaneously. 

 

4. Wiring                                                                                                                                                       

 

Before carry out any wiring work, it is essential to disconnect  the control unit from the mains 

supply.

 

Motor 

Open the wiring terminal block cover, connect motor as shown in Fig.4. 

Factory preset: 

 Wiring (PLC Input single-phase 220V, Output three-phase 220V) 

Y Wiring (PLC Input three-phase 380V, Output three-phase 380V) 

 

 

 

 

 

 

 

 

 

Fig.4 

Electromagnet brake 

Connect  power  wires  220V  (terminal  block  D,  N1  of  control  box)  to  yellow  wires  of  rectifier. 

Connect two wires of electromagnet to black wires. 

The non-excitation brake is adjust be 

 

 
 
 

 

 

 

Fig.5 

Manual operation 

V1

U1

W1

U2

W2

V2

W

V
U

V1

U1

W1

U2

W2

V2

W

V
U

~380V