P4. Automatic Closing
 

(1~9 minutes adjustable) (Fig.16) 

1.

 

Press and hold “SET” button for 4 seconds until ‘P1’ displayed.   

2.

 

Press “UP” button three times until ‘P4’ is displayed on the LED. 

3.

 

Press the “SET” button.   

4.

 

Press “UP” or “DOWN” to set auto close time (b0-b9). Press “UP” to increase timer, 

press “DOWN” to decrease timer.   

Note: Set timer to ‘b0’ to disable auto close function. 

5.

 

Press SET to confirm the setting. 

NOTE:   

 

When using auto close mode, a photo electric beam must be fitted correctly and tested for 
operation at regular intervals. Extreme caution is recommended when using auto close mode. 
All safety rules must be followed. 

 

 

Automatic closing is available only when the door is in fully opened position.

 

 

SET

UP

SET

UP

SET

UP

SET

UP

SET

UP

Press and hold “SET” button

for 4 seconds until ‘P1’ is
displayed

Press “SET” button to confirm

Press “UP” or “DOWN” to set auto

close time (b0-b9). Press “UP” to

increase timer, press “DOWN” to

decrease timer.

Note: Set timer to ‘b0’ to disable

auto close function.

Press “SET” button to confirm the

setting

Press “UP” button three times

until ‘P4’ is displayed on the

LED

 

Fig.16 

Содержание FBD180

Страница 1: ...Pty Ltd www totaldoorautomation com au sales totaldoorautomation com au Technical Support 1800 AUSTDA 1800 287 832 WARNING ONLY QUALIFIED AND EXPERIENCED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SER...

Страница 2: ...ist Tools needed for Installation Installation and Adjustment 6 Interface 10 Pushbuttons Transmitters Programming 11 P1 Open and Close Limit P2 Adjusting Obstruction Force Sensitivity P3 Infrared Phot...

Страница 3: ...ents When opening or closing the door do not attempt to walk or drive through the door The operator may only be repaired with the door closed The operator should be disconnected from mains power to av...

Страница 4: ...ruction during closing procedure The controller has a security LOCK function which prevents operation of the door from transmitter In the event of power failure the release device makes it possible to...

Страница 5: ...ssembly x1 6 Door bracket x1 5 Header bracket x1 10 Straight arm x1 13 Transmitter x2 R Pin Pin Screw M8x35 Screw cap M8 9 L arm x1 Screw M6x22 Screw M6x55 4 Operator bracket x2 8 Angle iron x1 11 7 s...

Страница 6: ...the door can be moved smoothly Check if there is a solid frame in the wall in the center of the door Close the door Locate the centre of the door Fit in the drive rail least 40mm space above the highe...

Страница 7: ...sten the four screws M6x22mm Straight arm Pin and R pin x1 M6x22mm Screw x4 The release arm towards the door opener Fig 4 Step 3 Place the opener on the floor Attach the opener to the chain drive rail...

Страница 8: ...and secure it with nut Pin long and R pin M8 Expansion bolt Not included in accessories Header bracket Fig 6 Step 5 Raise and support the opener with a ladder and line up the rail with the centerline...

Страница 9: ...5 and screw caps M6 Link the L arm to the door bracket with pin and R pin Link the straight arm to the shuttle with pin and R pin then connect L arm to straight arm with two screws M8X16 and screw cap...

Страница 10: ...T UP Fig 10 SET button initiates programming modes saves the settings UP button opens the door Increase settings in programming mode DOWN button closes the door decreases settings in programming mode...

Страница 11: ...lashing release the button until the door has reached desired position 4 Press SET to confirm the open limit position the LED will now indicated the CL 5 To set close limit press and hold DOWN button...

Страница 12: ...hold UP button OP on the LED display will be flashing release the button until the door has reached desired position Press SET to confirm the open limit position the LED will now indicated the CL To s...

Страница 13: ...sure it is working correctly and is TESTED by placing a 50mm high object on the floor Failure to follow the manual could result in serious personal injury and or property damage Photo electric beam m...

Страница 14: ...play to enable the photocell Press DOWN H0 will display to disable the photocell 4 Press SET to confirm the setting SET UP SET UP SET UP SET UP SET UP Press and hold SET button for 4 seconds until P1...

Страница 15: ...close mode a photo electric beam must be fitted correctly and tested for operation at regular intervals Extreme caution is recommended when using auto close mode All safety rules must be followed Auto...

Страница 16: ...on is available only when the door is in fully closed position Once the DOOR LOCK function is set the transmitter will also be locked To operate the garage door you need to unlock the transmitter firs...

Страница 17: ...nly when the Door Lock Mode is disabled 1 2 3 4 Fig 18 Adding Extra Transmitter learn Fig 19 1 Press LEARN until Su is displayed 2 Press the same new transmitter button twice 3 Of will be flashing 4 L...

Страница 18: ...nd hold LEARN button 2 11 will be displayed keep holding the LEARN button for 8 seconds until dL is flashing 3 All stored transmitters are being deleted SET UP SET UP Keep holding the LEARN button for...

Страница 19: ...R 19 8 External Terminal Connections 24V PE GND PB AC240V IN AC240V OUT Transformer Lamp Wall switch Infrared photocell N C Battery Motor RED BLACK Fig 21 Wicket door N C and Fire emergency WICKET DOO...

Страница 20: ...not light 1 Power is OFF 2 Fuse is blown 1 Make sure the power is ON 2 Replace the fuse After programmed the open and close limit the motor fails to work 1 The screws on the hall on motor are loose 2...

Отзывы: