Introduction

Congratulations on choosing the UbiquiSTAT™ room controller! The UbiqiSTAT series of controllers are feature rich, 

multifunction touchscreen devices providing extensive controls across a wide range of HVAC applications.
This guide will explain the initial setup of the UbiquiSTAT and guide you step-by-step through the built-in Startup Wizard, 

with which you can enter the basic configuration settings.

Refer to the 

UbiquiSTAT Installation Manual

 for instructions on installing, powering, and wiring the unit into your system. 

Refer to the 

UbiquiSTAT Configuration Guide

 for instructions on configuring the device, the communications network, 

and other devices that may be connected to this controller. Refer to the 

UbiquiSTAT BACnet Explorer Guide

 for advanced 

information on using the built-in BACnet Explorer to edit the device’s BACnet programming objects directly.
If you have any questions regarding your UbiquiSTAT room controller, do not hesitate to contact TCS Technical Support at 

800-288-9383, ext. 2. Our Technical Support Department hours are Monday – Friday, 7:00 a.m. to 7:00 p.m. (CST).

Setting Up the UbiquiSTAT

Complete the mounting, power, and RS-485 network wiring before setting up the UbiquiSTAT, as the face of the controller 

is not powered until the UbiquiSTAT is assembled (refer to the 

UbiquiSTAT Installation Manual

 for more information.)

Use the Startup Wizard when setting up the UbiquiSTAT for the first time or after resetting it to factory defaults. All 

controls are disabled until after completing the Startup Wizard.
The Startup Wizard will guide you through the following settings:

• 

Display Settings: Select temperature measurement (Fahrenheit or Celsius), clock type (12-hour or 24-hour), and 

display backlight preference (low, medium, or high).

• 

Date & Time: 

Set to the current time.

• 

Thermostat Type: 

Select whether the thermostat is controlling a conventional or heat pump HVAC system. 

• 

System Mode: 

Select between automatic, heating, cooling, or fan plus recirculation.

• 

Occupied Fan Mode: 

Determine the status of the HVAC system’s fan when the room is occupied.

• 

Communication Mode:

 Wired models allow for selecting between TCSbus or BACnet MS/TP communication modes. 

Wireless models allow additional selections for BACnet Wi-Fi or none, for use in stand-alone situations. 

• 

Network Address: This must be unique for each controller on the RS-485 network. The valid address range is from 1 

– 127. If you desire an address value of 0, you can enter this after completing the Startup Wizard.

• 

Baud Rate: Select the desired baud rate for your network. The baud rate defaults to 9,600 bps for TCSbus, and 38,400 

bps for BACnet MS/TP. All controllers on the network must use the same baud rate.

• 

Device Instance: This number must be unique across the entire BACnet network. The initial value shown is a 

combination of the TCS BACnet vendor ID (496) and the previously entered network address. This is done in an 

attempt to create a unique value. However, we encourage users to create their own numbering system for all 

controllers on the BACnet network.

• 

Wi-Fi Configuration: If BACnet Wi-Fi is available on your UbiquiSTAT, a series of screens will allow you to configure 

your UbiquiSTAT to the desired Wi-Fi network.

Содержание UbiquiSTAT

Страница 1: ...2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com 202211 Quick Setup Guide UbiquiSTAT Commercial BACnet Controller...

Страница 2: ...ry defaults All controls are disabled until after completing the Startup Wizard The Startup Wizard will guide you through the following settings Display Settings Select temperature measurement Fahrenh...

Страница 3: ...to the next screen STEP 3 On the DISPLAY SETTINGS screen select the desired Temperature UNITS Fahrenheit or Celsius CLOCK configuration 12 hour or 24 hour and BACKLIGHT setting Low Medium or High Pre...

Страница 4: ...creen STEP 6 On the THERMOSTAT TYPE screen select whether the UbiquiSTAT is controlling a CONVENTIONAL equipment or a HEAT PUMP Press the NEXT button to save the settings and advance you to the next s...

Страница 5: ...t Wi Fi pressing the NEXT button will save the settings and advance you to STEP 12 If you selected NONE pressing the NEXT button will save the settings exit the Startup Wizard and return you to the HO...

Страница 6: ...exit the Startup Wizard and return you to the HOME screen If you selected BACnet MS TP or BACnet Wi Fi in STEP 9 pressing the NEXT button will save the settings and advance you to the DEVICE INSTANCE...

Страница 7: ...ur changes STEP 15 After pressing the OK button in the previous screen you will see the CONNECTION STATUS screen When the UbiquiSTAT has successfully connected to the network a DONE button will appear...

Страница 8: ...button to advance you to the ADVANCED 2 2 Screen STEP 4 On the ADVANCED 2 2 screen press the FACTORY DEFAULTS button You will then be prompted with a warning message advising you that loading the fact...

Отзывы: