Field of application
The TOER2-EB is a door release relay for specific door release, if several front-door
stations and door opener are installed in one system. With the TOER2-EB the door,
which called last, is opened.
Can be used also for the evaluation of specific key functions of the indoor stations.
Can be used also to control additional bells and chimes.
With an own TCS:BUS connection for location-independent installation.
Suitable for the installation in flush-mount sockets.
Short description
potential-free relay contact
closing contact, 24 V DC / 2 A
Activating the device
not programmed: in case of an incoming door call
with the serial number of the TOER2-EB
programmed: additionally in case of an incoming
door release command to a specific front-door sta-
tion
Alternative activation through
programming
Programming the device can be implemented only
via TCSK or configo™.
evaluation of control functions
via parallel serial number (in case of a door call, in-
ternal call and pressing the floor push-button)
door release time
can be adjusted with TCSK or configo™
Factory setting: 2 sec
Installation
Notes on the installation
!
Observe when installing the device outdoors:
Avoid water from entering the device by suitable measures!
Wiring diagram