background image

 2 

11/2015

 

 

TCS TürControlSysteme AG, TCS Hotline Germany:  +49 (0)4194 98811-88

 

Subject to technical changes. 

FAX: 04194 9881-29,  E-Mail: [email protected], www.tcsag.de

 

PI_TOER2-EB_uk2  2A 

mi 

Field of application 

 

  The TOER2-EB is a door release relay for specific door release, if several front-door 

stations and door opener are installed in one system. With the TOER2-EB the door, 
which called last, is opened. 

  Can be used also for the evaluation of specific key functions of the indoor stations. 

  Can be used also to control additional bells and chimes. 

  With an own TCS:BUS connection for location-independent installation. 

  Suitable for the installation in flush-mount sockets. 

 
 

Short description 

 

potential-free relay contact  

  closing contact, 24 V DC / 2 A 

Activating the device 

  not programmed: in case of an incoming door call 

with the serial number of the TOER2-EB 

  programmed: additionally in case of an incoming 

door release command to a specific front-door sta-
tion 

Alternative activation through 
programming 

  Programming the device can be implemented only 

via TCSK or configo™. 

  evaluation of control functions 

  via parallel serial number (in case of a door call, in-

ternal call and pressing the floor push-button) 

door release time 

  can be adjusted with TCSK or configo™ 

  Factory setting: 2 sec 

 
 

Installation 

Notes on the installation 

!

 

Observe when installing the device outdoors:  
Avoid water from entering the device by suitable measures! 

 

Wiring diagram 

 

 

Отзывы: