Connect the lines
Connect the package components according to the wiring example home:packs.
!
Use the included small screwdriver to connect the lines and to avoid damaging the
device.
Front-door station (PAK or PUK) in 2-wire special operation
In this operation mode only one front-door station can
be connected!
A P-wire is to be realised by a bridge between terminal
a and P.
Note: The front-door station does not work, if the bridge
is connected to b instead of a.
Connect a door realease relay to the PAK or PUK
There is the possibility to connect a door release relay
if more than one front-door station is connected.
Please observe the product information of the
door release relay.
Connect the bell buttons to the built-in door loudspeaker ASI11000
The bell buttons provided by customer have to be
connected to the connection terminals (matrix points)
of the built-in door loudspeaker ASI11000 according to
the opposite illustration.
!
When installing additional (e.g. connected parallel ) comfort indoor stations, the max.
permitted number must be observed.
See product information indoor station.
Observe the information
Installation
and
Technical data
in the product information
ASI11000.
indoor station with number as on