01/2013
25
TCS TürControlSysteme AG, TCS Hotline Deutschland: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
Mail: [email protected]
PI_K30001-30004_uk 1A
Repair
Dismount front panel with modules
1.
Dismount the roof of the post.
2.
Loosen the two knurled screws, which are located inside at the upper edge of the post
to free the upper front panel with the modules.
3.
Push out the front panel upwards.
Installing a module into the front panel
4 x self-locking nut
module plate with
sealing
spacer foil, self-adhesive
0.5 mm thick each
front panel (1.5 to 2.5 mm
thick) with welding studs
1.
Stick 1 to 3 spacer foils on top of another from behind at the front panel cutouts.
2.
Put on the module with sealing.
3.
Fix the module with 4 self-locking nuts (enclosed in the delivery).
Display module AMI1010x-0000: Replace the EEPROM storage
!
Changes in datasets and parameter are not stored automatically.
After all modifications, carry out the following steps
Various configurations > Safe
storage
to transfer the changes on the EEPROM (see manual
Modules in front-door
stations
).
All programmed data such as serial numbers and parameter are stored within the
EEPROM. If the front-door station needs to be replaced, the EEPROM storage can be re-
moved from the programmed front-door station and installed into the new,
comparable
front-door station.
1.
Eventually safe the data of the display (
Various configurations > Safe storage
).
2.
Open the housing.
3.
Disconnect the display from the power supply: pull of the connecting plug.
4.
The EEPROM storage is positioned in the electronic part (similar to the display module).
Pull off the EEPROM storage.