2.

Use 1/4 in. O.D. copper tubing and connect the saddle 

valve to the inlet side of the solenoid valve.

a. Place the brass compression nut over the copper 

tubing.

b. Slide the brass ferrule over the tubing.

NOTE: Do not over-tighten the compression nut. 

Moderate tightness prevents leaking. 

c. Insert tubing into the solenoid valve fitting. Support 

the valve while tightening the compression nut.

3.

Connect a 1/2 in. hose to the humidifier drain fitting and 

run it to a suitable drain.

NOTE: Slope the hose downward for correct drainage.

CHECKING INSTALLATION

1.

Open the saddle valve.

NOTE: The furnace blower must be operating for the 

humidifier to work.

2.

Set the thermostat setpoint 10°F (12°C) above the room 

temperature.

3.

Set the humidity control to a high humidity setting, or 

place the humidity control in the test position.

4.

Observe the water running out of the drain line to be 

sure the humidifier is working correctly.

5.

Check for leaks.

6.

Reset the thermostat and humidity control to 

comfortable settings.

OPERATING HUMIDIFIER

The Total Comfort System HE360A Humidifier is controlled by 

the H8908 Humidistat. The humidistat is installed either on an 

interior wall in the living area, or on the return air duct. Choose 

the humidity control setting using the combination relative 

humidity/outdoor temperature setting scale on the humidity 

control dial. Match the dial setting to the outdoor temperature 

for optimizing the humidity level to reduce the moisture 

condensation on your windows. Table 1 can also be used to 

adjust the humidity control to the recommended setting.

NOTE: As outside temperature drops, the recommended 

humidity control setting is lowered to accommodate 

the effects of dewpoint. These settings should 

reduce the accumulation of moisture and ice on the 

windows and in other areas of the house.

Some indoor activities such as cooking, showering and 

clothes drying can cause excessive levels of humidity and 

start the accumulation of moisture on the windows. If this 

condition persists for more than a few hours, set the 

humidistat to the lowest setting to turn off the humidifier. If the 

condition does not improve, ventilate the house to remove the 

moisture.

OPERATION

The HE360A Humidifiers use the principle that vapor 

(evaporated water) is created when warm dry air blows over a 

water-soaked area. As the vapor circulates, the relative 

humidity rises.

The humidity control monitors the relative humidity and 

activates the humidifier accordingly. The humidifier has a 

water supply that disburses water over a humidifier pad. The 

warm dry air from the furnace passes over the humidifier pad, 

collects moisture, and circulates it through the house.

Since humidified air feels warmer and more comfortable, the 

homeowner may decide to lower the thermostat setpoint, thus 

saving money on heating bills. The end result is that the 

humidifier provides a more comfortable environment that is 

also energy efficient.

Table 1. Recommended Humidity Control Settings.

MAINTENANCE

A regular maintenance program prolongs the life of the 

humidifier and provides a more comfortable environment. 

Cleaning frequency depends on water conditions.

Either hard or soft water can be used in the humidifier, but 

hard water mineral deposits are more difficult to clean then 

soft water deposits.

Use the following procedure to clean the humidifier.

CAUTION

Personal Injury or Equipment Hazard.

Power Supply can cause electrical shock or 

equipment damage.

Disconnect power supply before performing humidifier 

maintenance.

IMPORTANT

Never oil any part of the humidifier.

Outside Temperature

Recommended Setting

-20°F (-29°C)

15

-10°F (-23°C)

20

0°F (-18°C)

25

+10°F (-12°C)

30

+20°F (-7°C)

35

Above +20°F (-7°C)

40

Содержание HE360A

Страница 1: ...ibution tray for optimal efficiency and water usage Proven technology used for high performance humidification Narrower footprint than popular compatible model while maintaining a common humidifier pa...

Страница 2: ...ged Total Comfort System Model Available HE360A Includes humidifier humidifier pad mounting template self piercing saddle valve and H908 Convertible Humidity Control Capacity At 120 F 49 C plenum temp...

Страница 3: ...in wc and water pressure is no greater than 125 psi Location and Mounting IMPORTANT Mount the humidifier at least 3 in 76 mm above the furnace jacket to allow adequate space for the drain line Check...

Страница 4: ...es and regulations H8908 Humidistat Wiring Connections IMPORTANT Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed If not using a current s...

Страница 5: ...should reduce the accumulation of moisture and ice on the windows and in other areas of the house Some indoor activities such as cooking showering and clothes drying can cause excessive levels of hum...

Страница 6: ...water nozzle back on the tray 17 Place the humidifier pad assembly in the humidifier housing and press until the assembly is seated 18 Be sure the water feed tube is placed in the guide slots of the...

Страница 7: ...y Condensation on walls Turn off humidity control and water until condensation is completely evaporated Heavy condensation on windows Turn down humidity control low enough to eliminate condensation ca...

Страница 8: ...ic Drive Golden Valley MN 55422 Scarboroug Ontario MiV 4V9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers HE360A POWERED FLOW THROUGH HUMIDIFIER Fig 7 Exploded vi...

Отзывы: