Installation
To be noted during connection
!
By installation outdoors: Prevent ingress of water into the device with appropriate ac-
tions!
!
•
Disconnect the supply voltages before working on the device!
•
Always remove the termination resistor. Only if the device is installed as the termi-
nal device at the end of a TCS:BUS video line, it has to be fitted!
•
For cable connecting auxiliar terminals are nessesary on site.
Cable cross sections for the connecting cables
Terminals
Cable cross section
Cable diameters
Connection terminals video output *,
Connection terminals TCS:BUS *
0.2 ... 1.5 mm
2
0.5 ... 1.4 mm
Connection terminals video input 1 and 2
0.2 ... 1.5 mm
2
0.8 ... 1.8 mm
* Video wire: twisted pair cable with diameter 0,8 mm
(e.g.
standard-telecommunication cable J-Y(St)Y 4x2x0,8)