background image

 5 

08/2006 

Installation 

To be noted during connection 

 

!

 

By installation outdoors: Prevent ingress of water into the device with appropriate ac-
tions! 

 

!

 

• 

Disconnect the supply voltages before working on the device! 

• 

Always remove the termination resistor. Only if the device is installed as the termi-
nal device at the end of a TCS:BUS video line, it has to be fitted! 

• 

For cable connecting auxiliar terminals are nessesary on site. 

 

Cable cross sections for the connecting cables 

 

Terminals  

Cable cross section 

Cable diameters 

Connection terminals video output *, 
Connection terminals TCS:BUS * 

0.2 ... 1.5 mm

2

0.5 ... 1.4 mm 

Connection terminals video input 1 and 2  

0.2 ... 1.5 mm

2

0.8 ... 1.8 mm 

 

*  Video wire: twisted pair cable with diameter 0,8 mm  
 (e.g. 

standard-telecommunication cable J-Y(St)Y 4x2x0,8) 

TCS TürControlSysteme AG 

 Geschwister-Scholl-Str. 7 

 D-39307 Genthin

 

Technische Änderungen vorbehalten. 

Tel.: 03933/879910  

  FAX:  03933/879911  

  www.tcs-germany.de

 

PI_GB_FVY1200-x600_Art0017593_1v0.doc mi 

Содержание FVY1200-0600

Страница 1: ...tributor FVY1200 0600 for flush mounting TCS T rControlSysteme AG Geschwister Scholl Str 7 D 39307 Genthin Technische nderungen vorbehalten Tel 03933 879910 FAX 03933 879911 www tcs germany de PI_GB_F...

Страница 2: ...ge lines minimum distance of 10 cm for joint cabling arrangements use of separators between high and low voltage lines in joint cable ducts use of standard telecommunication cables e g J Y St Y with 0...

Страница 3: ...lification adjustment 0 to 12 dB total Maximum output level 4 Vpp at 100 Ohm by 1 Vpp at input Application The FVY1200 0600 accepts an video signal and distributes it to two active independent outputs...

Страница 4: ...amplification 1 Minimum Voltage gain independent of output load Loop through up to 25 video distributors Minimum amplification 0 dB 1 Vpp Maximum amplification 12 dB 4 Vpp by 1 Vpp at input and 100 Oh...

Страница 5: ...iliar terminals are nessesary on site Cable cross sections for the connecting cables Terminals Cable cross section Cable diameters Connection terminals video output Connection terminals TCS BUS 0 2 1...

Страница 6: ...witch button auxiliar terminal Wiring diagramm 5 wire connection Wiring diagramm 6 wire connection TCS T rControlSysteme AG Geschwister Scholl Str 7 D 39307 Genthin Technische nderungen vorbehalten Te...

Страница 7: ...setup the FVY1200 as terminal device Fitted horizontal fitted to both upper contacts the video distributor is instal led as the terminal device at the end of a TCS BUS video line It activates the term...

Страница 8: ...ion 1 Create a voice communication via the second person through the door communication system See also the product information and operating instructions for the connected in house and front door sta...