16
Commissioning
!
First install the system completely, than connect it to
the mains voltage!
Install the devices of the system completely.
V1 and V2 must not be connected with the P-, a- or b-wire. When
connecting the video wires V1 (+) and V2 (−) the polarity must be
observed.
Proof the a-, b- and P-wire against each other for short-circuits.
Switch on the main voltage.
Error detection and indication
Errors are signalled optically and acoustically: single error tone and per-
manent flashing of both LEDs.
error cause
indication
error mode
error tone
our solution
a- and P-wire are
mixed or short-
circuited
both LEDs
are flashing
change a- and P-wire or remove
short-circuit,
device is in standby mode again
a- or M-wire not
connected or not
supplied
connect the a- or M-wire or check
the power supply,
device is in standby mode again
button stucks
(press longer than
15 seconds)
remove button at the IVW2211 or
floor push button, device is going
into standby mode again