5
02/2013
TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
PI_bre2eb_uk 1 A
Adjust the switch time of the output
BRE2
shortly press,
LED blinks
Press until (time),
as the relay should be activated
after the required lapse of time is over
release, the LED expires
switch time is adjusted
Allocate a BUS action to the input
BRE2
press until
release
the LED lights up
press door opener or
press floor push-button
or...
(free BUS actions by
entry via Service Device
TCSK-01)
press until the
release,
LED lights up shortly
LED OFF
execute required BUS action
input is allocated to BUS actions
Reload factory setting
2
:
switch time of the output = 1 s, input sends door release protocol AS=0
BRE2
press until
release
the LED is ON
press until the LED
release
expires shortly, is ON, expires
programming deleted
2
) Factory setting is identical to delivery state.
Conformity
Declarations of conformity are available under www.tcsag.de, Downloads, trade