©TCP, Inc. 2008/02630b
TCP, Inc.
325 Campus Dr. | Aurora, Ohio 44202 | www.tcpi.com | Customer Service: 800.771.9335
Fixture Installation
1
Remove the metal mounting
bracket and threaded rod from
the hardware kit. Fixture mounts
to a standard junction box using
the provided metal strap. (Fig1)
Fig. 1
2
Attach the metal strap to the
junction box using the two screws
provided. (Fig. 2)
Fig. 2
3
Remove the fixture’s lens diffuser by removing the Philips
screw. Set screw aside for future use. Lift and slide the
diffuser down and remove it from the fixture. Remove the
enclosed bulb and set it and diffuser aside.
4
Match up the white and black
wires from the fixture to the
black and white wire in the
junction box and connect
together using the provided wire
nuts. (Fig. 3)
6
Remove the bubble wrap from around the
bulb and insert the proper GU24 base
fluorescent lamp into the socket. Hold the
lamp by the base, insert the two pins into
the two curved slots in the socket and twist
clockwise until the bulb “seats.” CAUTION:
DO NOT HOLD THE LAMP BY THE GLASS
DURING INSERTION OR REMOVAL TO
PREVENT ACCIDENTAL BREAKAGE.
7
Reapply the fixture’s cover and secure it with the Philips screw
previously removed.
Replacement Parts:
White Wallpack Body w/ lens, no lamp: 570BKPCGU
Black Wallpack Body w/ lens, no lamp: 570WHPCGU
Fixture
57027BPCGU
57027WPCGU
57032BPCGU
57032WPCGU
57042BPCGU
57042WPCGU
Replacement Lamp
33127SP
33127SP
33132SP
33132SP
33142SP
33142SP
Replacement Lamps:
8
Restore power to the electrical box.
Bulb Replacement Instructions
Troubleshooting Guide
Fig. 3
Fig. 4
5
3
1
4
Your bulb should last up to 10,000 hours in normal use. When bulb
replacement is necessary, you must replace the bulb with a
self-ballasted GU24 base fluorescent bulb. These bulbs are readily
available at your local home center and most larger hardware stores.
Remove the old bulb by grasping it
firmly at the plastic base of the bulb
and firmly twist the bulb counter-
clockwise until it “unseats” and lines
up with the large end of the
openings (Fig. 3). Pull straight down.
Be careful not to drop the bulb.
Grasp the replacement bulb in
the same manner and re-insert
the replacement bulb into the
socket and twist the bulb
clockwise until it ‘seats’ (Fig. 4).
Do not force the bulb into the
socket or twist forcefully.
Restore power to the fixture.
Shut off power supply. Allow sufficient time for bulbs to
cool properly before handling.
2
Remove the fixture’s diffuser by removing the Philips screw.
Minor problems often can be fixed without the help of an electrician. Before doing
any work on the fixture, shut off power supply at the circuit breaker panel to avoid
electrical shock.
Minor problems often can be fixed without the help of an
electrician. Before doing any work on the fixture, shut off power
supply at the circuit breaker panel to avoid electrical shock.
Problem
Cause
Solution
Fixture doesn’t light
Bulb is defective
Replace bulb
Power is off
Check if power
supply is on
Bad wire connection
Check wiring
Bad switch
Test or replace
switch
Fuse blows or circuit breaker trips Crossed wires or power
Check wiring
when light is turned on
wire is grounded out
connections
Light bulb flickers
Light is being
Attach rubber
reflected back to
sensor hood over
the sensor
top of light sensor
570 Series GU Wall Pack Fixtures
Installation Instructions
Fig. 5
5
Tuck the wires into the junction
box and push the fixture base
over the threaded rod. Secure
fixture by adjusting the stud length
into the mounting bracket and
with the stud cap. Orientation of
fixture is base up.
Fig. 4
Fig. 3