Test and Alignment Specification for MT58 Series (v0 01)
160523
Page 14 of 26
Important:
If measurements are performed on whatever else LED panel with Minolta CA210
, it’s required to
calibrate additional channel (ex: CH01) using relative following offsets (CH00 remains for CCFL panel):
+0.002
for “
x
”
and
+0.012
for
“
y
”.
Note
⑧:
See WB list as follows for more details.
Cloning
Once a TV is well aligned and prepared (channels maps, volume, picture presets, …) , user can prepare golden
clone image that can be copied on demand to all further TV production lot of same TV. To access cloning function, you
can select
“
Factory menu
USB Clone && Update
All Clone/CH Clone/User data Clone
” , Scroll down to “
TV to
USB
” or “
USB to TV
” and press RCU “
OK/
►” key to process. 4 BIN images can created, overwritten or read on USB
stick (pen driv
e) depending on chosen template like following: “
database\applications\database\***.db
” . These files
need to be used strictly with MT58 SoC platform as depending on SW structure.
Other faster access methods via UART/IR commands
are available on enclosed SIACP requirements (rev. v3.9).
2.4. High Pot. and Insulating Resistance Tests
At the end of the process, a “High Voltage” and an “Insulating Resistance” tests are required to fulfil Safety
Electrical requirements (CEI 65065).
High Voltage Withstanding requirements
Insulating Resistance requirements
-
“Voltage”
3500
VAC
-
“Voltage”
500 VDC
-
“Max Leakage Current”
10 mA
-
“Threshold Min”
4M
Ω
-
“Test Time”
3 sec
-
“Test Time”
2 sec
2.5. SHOP-END Test
At f
inal process stage, it’s necessary to perform “
Reset shop
” before any packing to leave Factory mode and
restore User default presets.
This function is accessible by selecting
“
Factory menu
Reset Shop
”, then pressing RCU “
OK/
►” key. Other
faster methods via UART/IR commands are available on enclosed SIACP requirements (rev. v5.4).
Note
⑨:
A password might be required in case of Parental Control function is locked, use default “
1234
” password or
“
0423
” super password to clean-up existing ones if forgotten.
END
Appendix
⑴
“How to upgrade SW FLASH using MTK tool”
Download boot bin
“ tcl_m1v1_eu_secure_emmcboot.bin” & blank upgrade main software“V8-T658T01.pkg”
from the software website.
Connect UART interface to suitable manufacturing TV input connector, upgrade boot bin first to blank IC.
1) Turn on your TV, then connect the Serial Interface to USB debug port.
Содержание U65S9906
Страница 10: ...Test and Alignment Specification for MT58 Series v0 01 160523 Page 5 of 26...
Страница 47: ...Trouble Shooting No Picture 51...
Страница 48: ...Trouble Shooting No Sound 52...
Страница 49: ...Trouble Shooting Abnormal Picture 53...
Страница 50: ...Trouble Shooting Network Fault wired 54...
Страница 51: ...Trouble Shooting Network Fault wireless 55...